35292798
tender for repair maintenance of specialized electrical & mechanical services at tis hazari court, delhi. ( sh: miscellaneous works attis hazari court new delhi ) rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable and 1.5 sq. mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required. a ) group c 2 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required.a ) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 3 b ) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 4 c ) 2 x4 sq. mm + 1 x 4 sq. mm earth wire 5 supplying and drawing of following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. a ) 3 x 1.5 sq. mm 6 b ) 3 x 4 sq. mm 7 c ) 3 x 6 sq. mm 8 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection etc. as required. 9 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 25 amps modular socket outlet and 25 amps modular mcb, connection etc. as required. 10 supplying and fixing of following size / modules, gi / pvc box alongwith modular base & cover plate for modular switches in recess etc. as required.a ) 6 module ( 200 mmx75 mm ) 11 b ) 8 module ( 125 mmx125 mm ) 12 c ) 12 module ( 200 mmx150 mm ) 13 supplying and fixing following modular / piano switch / socket on the existing modular / piano plate & switch box including connections but excluding modular plate etc. as required.a ) 5 / 6 a modularswitch 14 b ) 6 pin 15 / 16 amp modular socket outlet 15 c ) 15 / 16 amp modular switch 16 d ) bell push 17 e ) two module stepped type electronic fan regulator 18 providing, installation, testing and commissioning of non return valve of following sizes confirming to is: 5312 complete with rubber gasket, gi bolts, nuts, washers etc.as required :a ) 150mm dia 19 supplying, fixing, testing & commissioning of double flanged sluice valve of rating pn 1.6 with non rising spindle, bronze / gun metal seat, isi marked complete with nuts, bolts, washers, gaskets and conforming to is 780 of following sizes as required :a ) 150mm dia 20 supplying and fixing following way, horizontal type tpn / spn, sheet steel, mcb distribution board, 415 / 230 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted, earthing i / c etc. dismantling of existing worn out db after opening of connections as required. ( but without mcb / rccb / isolator ) a ) 4 way ( 4 + 12 ) , double door, tpn 21 b ) 8 way, double door, spn 22 supplying & fixing of following accessories in the existing tpdb / m.s. box i / c connections testing, commissioning etc. as reqd.a ) 5 32 amp. sp mcb 23 b ) 63 amp. tpn mcb 24 c ) 63 amp. spn mcb 25 supplying & fixing ofenergy efficient 150 watts led flood light with suitable mounting arrangement including connection, testing etc. as required.the total minimum system efficacy of fitting should be minimum 100 lumen / watt colour temperature 5500k to 6500k, power factor>0.95, cri ( ra ) >75, thd <10%, with apfc driver having driver efficiency >85%, operating voltage 150 270 volts with minimum 4.0 kv surge protection, working lifetime: >50000hours.the led chip should be of cree, nichia, philips lumiled, osram, edison ) 26 supplying & fixing ofenergy efficient 200 watts led flood light with suitable mounting arrangement including connection, testing etc. as required.the total minimum system efficacy of fitting should be minimum 100 lumen / watt colour temperature 5500k to 6500k, power factor>0.95, cri ( ra ) >75, thd <10%, with apfc driver having driver efficiency >85%, operating voltage 150 270 volts with minimum 4.0 kv surge protection, working lifetime: >50000hours.the led chip should be of cree, nichia, philips lumiled, osram, edison ) 27 supplying, installation, testing & commissioning of led recessed luminairewith led ( light emitting diode ) system power: 36w, colour temperature of 5700 k, neutral white, 230v constant current driver, 70% of luminous flux after 50, 000operating hours, energy efficient leds, cri>80, luminous flux of3600lm, electronic control gear, direct light emission, crca frame, polyester white powder coat applied over a 5 stage pre treatment, prismatic diffuser for glare free uniform light, ugr<19, protection class i, ip40, macadam 3, t.h.d= 10%, driver efficiency = 88%, surge protection of 2.5kv, l = 595mm, b = 595mm, h = 70mm etc complete as required. 28 supplying, installation, testing and commissioningof 36 watt 4 feet wall mounted led batten fitting with aluminum housing and integrated electronic driver including connections with 1.5 sq.mmm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 29 supplying, installation, testing & commissioning of led recessed luminairewith led ( light emitting diode ) system power: 30w, colour temperature of 5700 k, neutral white, 230v constant current driver, 70% of luminous flux after 50, 000 operating hours, energy efficient leds, cri>80, luminous flux of 3600 lm, electronic control gear, direct light emission, crca housing, polyester white powder coat applied over a 5 stage pre treatment, prismatic diffuser for glare free uniform light, ugr<19, protection class i, ip40, macadam 3, t.h.d= 10%, driver efficiency = 88%, surge protection of 2.5kv, l = 1195mm, b = 295mm, h = 70mm etc complete as required. 30 supplying & replacement of energy efficient 1400 mm sweep size ceiling fan, includingsuitable length of down rod & wiring with 1.5 sq. mm frls pvc insulated, copper conductor, single core cablealongwith suitable mounting arrangement etc. as required. 31 supplying & replacement of 380 / 400 mm sweep size 230 volts, single phase, 50 hz wall fan with suitable mounting arrangement including connection with 1.5sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. 32 supplying, installation, testing and commissioning of 250 mm sweep size fresh air fan with louver shutter 230 volts, single phase, 50 hz including making the suitable hole andrepairing the damages and making good same including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. 33 supplying & fixing of 450 mm sweep900 rpm heavy duty exhaust fan 230 volt 1 ph 50 hz in the existing holei / c repairing the damage as same i / c connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as reqd. 34 supplying & fixing of 600 mm sweep 230 volt 1 ph 50 hz ac industrial type metal frame air circulator on the wall with suitable mounting arrangement i / c connection with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as reqd. etc. as reqd. 35 supplying & fixing of 450 mm sweep 230 volt 1 ph 50 hz ac industrial type air circulator on the wall with suitable mounting arrangement i / c connection with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as reqd. etc. as reqd. 36 supplying, laying and fixing of following size dlp pvc trunking systemfor cable management system / raceways i / c separation partion for trunking if reqd., plastic clip on partiotin, body joints for aligning bases during installation, end caps and all other accessories necessary for installationsin surface / recess i / c connections etc. as reqd. a ) 100 mm x 50 mm nominal height 37 b ) 50 mm x 50 mm height...
Due Date : December 21, 2022
Tender Value : ₹ 28.65 Lakhs