28450830
improvement of water supply by replacement of oldmonoblock pump sets alongwith other allied works atmotia khan small pump house under ae ( eandm ) ii , replacement of old monoblock pump sets by carrying following works: s/o monoblock pump sets suitable for clear water tefc 25 hp motor f class insulation three phase , 50 hz speed 3000 rpm , ac supply having the discharge 26 14 lps and head 44 58 mtr working on 415+5% volts . the pump should be fitted with ci casing ci impeller shaft of c 40 having suction and delivery of size 100 x 80 mm . make: kirloskar/crompton , dismantling of monoblock p/set by disconnecting electric connection , removing the existing damaged m . s . base frame from the foundation by cutting of nut & bolts with the help of gas cutter and man power etc . as required and old material shifted to the store as per direction of site in charge . , breaking of cc foundation with the help of pneumatic hammer i/c manual & heavy labour taking out the existing damaged foundation bolt etc . , making of new cc foundation with suitable ratio of gravels , sand and cement as per standard size suitable for above p/set i/c ms foundation bolts as required . , providing of ms base frame for mounting of 25 hp monoblock pump set complete as per site requirement . , fitting of m . s . base frame on c . c . foundation after proper alignment/level , fitting of p/set on the base frame with the help of necessary material as required . , installation of above pump sets on the ms base frame with proper alignment , taking all safety precautions arranging all tools & tackles etc . and connection the motor from panel to starter . , renovation of delivery line of size 100/80 mm by carrying following works: dismantling of sluice valve and nrv from existing system with the help of gas cutter for cutting of nut & bolt and taken out from existing line with the help of heavy labour and old material shifted to the store as per direction of site in charge . , supply of m . s . black pipe 100mm dia c class heavy duty . make: jindal/tata , supply of m . s . black pipe 80mm dia c class heavy duty . make: jindal/tata , supply of 100mm dia flange thickness size 12mm as per site requirement . , supply of 80mm dia flange thickness size 12mm as per site requirement . , supply of ci double flanged spindle sluice valve pn 1 . 0 is 14846 ci body/wedge/bronze ring/ss 410 shaft construction and ss is 6603 gr 12 , cr12 of 100mm size make: kirloskar/ivc/djb approved make . , supply of ci double flanged spindle sluice valve pn 1 . 0 is 14846 ci body/wedge/bronze ring/ss 410 shaft construction and ss is 6603 gr 12 , cr12 of 80mm size make: kirloskar/ivc/djb approved make . , supply of ci swing type non return valve as per is 5312 pn 1 . 0 ci body , door/bronze to rubber rings/ss 410 hinge pin of 80 mm size . make: kirloskar/ivc/djb approved make . , s/o pressure gauge of 100 mm dia having required range with accessories such as gi fitting bib cock etc . as required to complete the work . make: feibig/h guru/djb approved make . , s/o different size of nut & bolts of good quality . , s/o rubber insertion jointing sheet conforming is 638/79 with isi mark 3 mm thick make: jyoti or any other make approved by djb , making and laying the complete line with the above material with the help of cutting , welding and grinding etc . as per site requirement . , painting the above job with two coats of anti corrosive paint after fittings all valves , bends etc in original position with complete civil works and testing/commissioning on full load i/c cartage etc . , repair/renovation of lt panel and other works by carrying out the following works: dismantling of all damaged switchgears , measurement instrument , indicating lights , relay , cleaning of dust , spider web , foreign particles etc . and removing of complete wiring and connection at site . , mccb 415 v , four pole high breaking capacity 50 ka 50 hz , 400 amp with spreader and handle make l&t/siemens , mccb 415 v , three pole 3 phase high breaking capacity 50 ka 50 hz , 100 amp with spreader and handle . make l&t/siemens , mcb single pole 6 amp . make l&t/havells , s/o single core copper conductor pvc insulated , 1100 volts of size 95 sq . mm make: finolex/havells , s/o copper tube terminal heavy duty thimbles of size 95 sq . mm . make: dowells/djb approved , s/o led street light 60w , pressure die cast aluminum housing with heat resistant , toughened glass and ip66 protection . make: cg/havells/bajaj , s/o ceiling fan 240 v 1200 mm sweep size . make: crompton/havells/orient , overload relay 45 75 make: l&t/siemens , over load relay 4 . 5 7 . 5 make: l&t/siemens , digital amp . meter make: ae/l&t , digital volt meter . 0 500 v make: ae/l&t , motor protection relay . make: l&t /siemens , power contactor 220v 3 phase 70 amp . make l&t/siemens , power contactor 220v 3 phase 50 amp . make l&t/siemens , star delta timer on delay . make: l&t /siemens , indicating lights led type ryb and on/off . make: l&t / havells , current transformer 300/5 , 100/5 , 40/5 . make: ae/advance , on load changeover switch 200 amp . open execution type . make: l&t/havells , fitting of the above components in panel enclosure with terminal blocks , channels , ferrules , thimble , support insulator on bus bar , required hardwares complete in all respect . , painting of complete panel board as required at site . , testing and commissioning of panel , as per required parameters with relevant is , testing of the panel prior to switching on as follows: i continuity and earth testing ii meggering of all equipments for phase to phase , neutral to body , neutral to earth and phase to earth iii checking for all tightness of nut and bolts iv alignments of doors etc . interlocking tests . all functional tests ...
Tender Value : ₹ Ref. Documents