Institute Of Genomics And Integrative Biology - Delhi
35449676 tender for supply, installation and commissioning of high pressure binary gradient solvent delivery system with autosampier and compatible detector system...
35449676 tender for supply, installation and commissioning of high pressure binary gradient solvent delivery system with autosampier and compatible detector system...
35428136 tender for high pressure binary gradient solvent system with autosampler and compatible detector system, etc high pressure binary gradient solvent system with autosampler and compatible detector system 3 ups; 5kva online ups with 30 min backup on full load 4 pc: i7, ram 16 or above, 1 tb ssd 5 printer printer laser jet black and white of repute brand, necessary software...
35337351 purchase of high performance liquid chromatography ( hplc ) for wazirabad laboratory , hplc for chemical section wazirabadwith the specification below : • system should be supplied with pumps, detectors, sample tray, columns, valves etc required to run the complete protocol used for the water sample. • system should be comprehensive and flexible • isocratic system, binary gradient system, quaternary gradient system should be available. • should have an option of detection capabilities include dad, uv / vis, fl, ri and elsd. • stable and reliable • advanced usb chip and optoelectronic isolation technology ensuring stable communication. • system should be simple and safe • powerful software makes it simple to control, capture, manage and analyse • real time pressure display, maximum and minimum pressure warning ensure the security product parameters technical parameters: high pressure constant flow pump 2 set flow rate range: 0.001ml / min 10.000ml / min, flow accuracy: =±0.2% flow precision: rsd=0.06%, maximum pressure: 45mpa pressure accuracy: =±3.0% , pressure pulsation: =0.1mpa uv / vis detector linear: 2.0au , wavelength range: 190 700nm wavelength repeatability: =0.1nm, wavelength accuracy: =±1.0nm band width: 8nm, response time: 0.0s 5s baseline noise: =±0.5×10 5au, drift: =1.0×10 4au / h path length: 10 mm ( analytical cell ) data processing workstation internal and external standard calculation methods automatically displays, prints, exports and starts other programs after the completion of a pmeasurement. comply with the requirements of the 21 cfr part 11 directive of the fda system kits 1 set power supply ac110 / 220v±10%, 50 / 60hz optional accessory: should be available with the supplier and price should be quoted as optional for individual part column oven, autosampler, degasser, diode array detector, refractive index detector, evaporative light scattering detector, fluorescence detector...
34663520 purchase of high performance liquid chromatography ( hplc ) for wazirabad laboratory , hplc for chemical section wazirabadwith the specification below : system should be supplied with pumps, detectors, sample tray, columns, valves etc required to run the complete protocol used for the water sample. system should be comprehensive and flexible isocratic system, binary gradient system, quaternary gradient system should be available. should have an option of detection capabilities include dad, uv / vis, fl, ri and elsd. stable and reliable advanced usb chip and optoelectronic isolation technology ensuring stable communication. system should be simple and safe powerful software makes it simple to control, capture, manage and analyse real time pressure display, maximum and minimum pressure warning ensure the security product parameters technical parameters: high pressure constant flow pump 2 set flow rate range: 0.001ml / min 10.000ml / min, flow accuracy: =±0.2% flow precision: rsd=0.06%, maximum pressure: 45mpa pressure accuracy: =±3.0% , pressure pulsation: =0.1mpa uv / vis detector linear: 2.0au , wavelength range: 190 700nm wavelength repeatability: =0.1nm, wavelength accuracy: =±1.0nm band width: 8nm, response time: 0.0s 5s baseline noise: =±0.5×10 5au, drift: =1.0×10 4au / h path length: 10 mm ( analytical cell ) data processing workstation internal and external standard calculation methods automatically displays, prints, exports and starts other programs after the completion of a pmeasurement. comply with the requirements of the 21 cfr part 11 directive of the fda system kits 1 set power supply ac110 / 220v±10%, 50 / 60hz optional accessory: should be available with the supplier and price should be quoted as optional for individual part column oven, autosampler, degasser, diode array detector, refractive index detector, evaporative light scattering detector, fluorescence detector...
27855231 binary gradient hplc system with uv and refractive index ( ri ) detectors and accessories items...
27855226 binary gradient hplc system with pda and refractive index ( ri ) detectors and accessories items...
27624737 binary gradient hplc system with uv and refractive index ( ri ) detectors and accessories items...
27624722 binary gradient hplc system with pda and refractive index ( ri ) detectors and accessories items...
13013421 tender for transmission electron microscope ultra microtome, binary gradient hplc pda detector....
13012031 tender for transmission electron microscope , ultra microtome , binary gradient hplc with pda detector...
12567505 purchase of transmission electron microscope, ultra microtome, binary gradient hplc with pda detector, water purifier & chemidoc gel imaging system...
2877289 supply of modular binary gradient hplc system....
2390544 purchase of binary gradient hplc with chiral columns from the project rp 02446...
1830147 supply of binary gradient semi preparative high performance liquid chromatography system...