New Delhi Municipal Council - Delhi
39914768 improvement to bakkarwala housing complex. sub head. construction/installation of one no. bore well/ tube well at bakkarwala housing complex...
39914768 improvement to bakkarwala housing complex. sub head. construction/installation of one no. bore well/ tube well at bakkarwala housing complex...
39812307 job required for development of bore well and repair / replacement of gi column pipe and submersible cable at kabul line and baird place area of age ( u ) water supply no ii under ge ( u ) water supply delhi cantt...
39746715 renovation of e and m equipments at sangam park tube well in ac 18. re invite door type 7.5 to 10hp lt cubical type electrical panel board floor / wall mounted of welded construction of size 1370mm x 760mm x 460mm fabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i / c powder coating , vermin proof having following items. 1. mccb 63 amp, 4 pole 1no. 2. rccb / elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no 3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no 4. digital ampere meter 96mmx96mm square shape of 0 30 amp range 1no 5. digital voltmeter of 96mm x 96 mm square shape of 0–500 volt range with selector switch 1no 6. led indicating lamps with fitting ( a set of 3 lamps ) 1set 7. shunt capacitor of 5 kvar with three phase isolator 1no 8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage low voltage protection. 1no 9. programmable time switch ( i.e., ryb phase & facility to change over from automatic to manual & vice versa ) up to 10 h.p.1no 10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc. as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame. make: all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved. 2 supply of kit kat board made out of wooden having 3 nos. 100 amp ( 415 volts re wireable ) kit kat of havells / standard / djb approved make. 3 supply of pvc insulated pvc sheathed, copper flat submersible conductor ( flexible ) cable, size 3 core x 6 sq mm , 1100 volts, conforming to is 694 . make: havells / finolex / djb approved make 4 supply of energy saving & environment friendly, pressure die cast aluminum housing 45 watt led street luminaries. make: havells / bajaj / crompton / dib approved make 5 supply of 50mm dia. b class gi pipe length 3 mtr. with duly welded flange in both sides, complete with cutting of flange for cable and welded support in both flanges.make: jindal / parkash / surya / tata / tata / jindal hisar / jindal gaziabad / isi 6 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and other end threaded of 50mm dia. make: jindal hisar / jindal gaziabad / isi 7 supply of nut bolts, washer, spring of sizes as per site requirement. 8 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. djb sor 9 supplying and laying 25 mm x 5 mm g.i strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm. djb sor 10 workmanship charges for lowering the submersible pump set one no. in bore well, fixing / erection / installation of e&m equipments, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e. eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the all sundry items which are useful & necessary for operation of tube well shall be deemed to have been included, such items are especially in specification as per site requirement....
39670430 boring/drilling bore well in premises of ggsss mukundpur (school id.1207230),delhi....
39498891 erection of repair to govt. girls sr. sec. school, samalka, new delhi. sh new bore well of 700 ft. depth and supply, installation, testing and commissioning of 7.5 hp bore well submersible pump set 1821280...
39409175 supply installation testing commissioning of submersible pump set with all enm equipment for 02 nos. newly developed tube well against defunct bore wells in premises of pkt 9 a dda flat jasola vihar in okhla constituency ac 54...
39353219 tender for construction of bvk / com hallsub head:provision of bore well for community hall at srs colony sector 7 dwarka ( ac 37 ) ....
39350689 tender for job work required for development and replacement of gi column pipe of bore well at mall road area of age(u) water supply no ii under ge (u) water supply delhi cantt...
39301701 repair and maintenance of infrastructure assets in r i division during 2023 24 sh supplying, installation and commissioning 45 hp submersible bore well electric motor pump set in windsor place roundabout fountain system...
39291020 repairing / renovation of electrical and mechanical equipments of tube / well no.01 installed at tahirpur bps. 1 supply of panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for operation of 10 15hp submersible pump set with automatic phase corrector, made out of 2mm thick crca sheet for load bearing members, totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. each part of the fabricated panel will be strictly subjected to seven tank treatments. the various components, assemblies and sub equipment of the panel will be as per standard given in relevant is. the bus bar shall be aluminum rectangular cross section size 20 mm x 5 mm strip per phase, rating 100 amp. the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. the bus bar will be covered with heat shrinkable pvc sleeve throughout in red, yellow & blue color to identify three phases & black for neutral. the bus bar support insulator made of non deteriorating, vermin proof, non hygroscopic materials such as smc / dmc. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a copper ferule crimped to the wire. the panel will have ms angle stand in 50x50x5mm size. size of panel 1360 mm ( h ) x 760 mm ( w ) 300mm ( d ) .having mccb 63amp. 415v, 50hz 18 ka tpn of high breaking capacity, 1 no., power contactor 220v 32amp. 3 nos. ( with aux contact block ) , thermal overload protection relay 9 15 amp. 01 no., star delta timer 01 no., digital timer switch 01 no., motor protection relay ( under voltage / over voltage / under current / dry run / single phase preventer ) 8 22 amp. 1 no, capacitor unit ( 5 ) kvar 1 no., indicating lights ryb 6 nos., on off 1 set, amp. meter digital 0 50a size 96 x 96 mm 1 no., volt meter ( digital type ) 0 500v size 96 x 96mm 1 no, controls mcb tpn 32 amp. 1 no., mcb sp 32 amp. 1 no., amp. & volt meter selector switches 1 set, ( auto manual reset, 2co contact ) 1 no. change over switch 1 no., terminal block 6 way 1 no., make of accessories: mccb / mcb: l&t / siemens / havells, power contactor: l&t / siemens, timer / relay: l&t / siemens, switchs / push button: l&t / siemens / havells, amp / volt meter: ae / l&t, indicating lights: havells / l&t. 2 supply of pvc insulated pvc sheathed, copper conductor ( flexible ) flat cable, size 3 core x 6 sq mm , 1100 volts, conforming to is 694. make: havells / finolex / polycab / any djb approved 3 supply of lt power aluminum cable, solid xlpe, insulated pvc armoured 650 / 1100 volts, v grade as per is 7908 part i 1988 size 3.5 x 25 sq mm. make: havells / finolex / polycab / any djb approved 4 supply of kit kat board made out of wooden having 3 nos. 100 amp ( 415 volts re wireable ) kit kat of havells / standard / djb approved make. 5 insulating mats for electricial purpose confirming to is 1562 / 2000 of following sizes, 3mm thickness sor ( e&m ) item code 22.5.3 6 led ( tube light ) decorative ultra slim square profile led lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. lamp type order, 20 w led 6000 k, sor ( e&m ) item code 19.1.2 7 supply of 80mm dia. b class gi pipe length 3 mtr. with duly welded and threaded flange in both sides, complete with cutting of flange for cable and welded support in both flanges as per site requirement. make: jindal / parkash / surya / tata. 8 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and another end threaded of 80mm as per site requirement. 9 supply of 80mm dia. gi bend with both side flanges duly welded and threaded as per site requirement. 10 supply of m.s. clamp of ms strip duly hole for holding the pipe of 80mm dia. with nut bolts and washer. 11 supply of m.s. bore cover made out of ms plate suitable for 12 / 14 dia. bore complete with suitable hole for passing the 80mm dia. gi pipe 12 supply of nut bolts, washer of good quality as per requirement 13 supply of rubber packing sheet with 50 % neoprene ( 1.5 mm to 25 mm ) isi mark. ( payment will be made as per actual ) . sor ( e&m ) item code 22.6.1 14 fabrication / supply of venturi assembly 80 mm dia. with complete accessories as required at site. 15 supply of electrical dozing pump ( 4lph, 5.5 kg / cm, supply chemical grade tank of 100ltrs with nrv, foot valve with nrv, injector valve and tube ( pipe ) etc make: clormax / milton roy 16 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm.frls pvc insulated copper conductor single core cable etc. asrequired. sor ( e&m ) item code 31.8.3 17 workmanship charges for lowering the submersible pump set one no. in new bore well, fixing / erection / installation of e&m equipment, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e., eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the tube well will be commissioned on automation mode and timing to be set as per direction of engineer in charge. the all sundry items which are useful & necessary for operation of tube well in automation mode shall be deemed to have been included, whether such items are especially in specification or not....
39290986 repairing / renovation of electrical and mechanical equipments of tube / well installed at zeenat mahal school. 1 supply of panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for operation of 10 15hp submersible pump set with automatic phase corrector, made out of 2mm thick crca sheet for load bearing members, totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. each part of the fabricated panel will be strictly subjected to seven tank treatments. the various components, assemblies and sub equipment of the panel will be as per standard given in relevant is. the bus bar shall be aluminum rectangular cross section size 20 mm x 5 mm strip per phase, rating 100 amp. the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. the bus bar will be covered with heat shrinkable pvc sleeve throughout in red, yellow & blue color to identify three phases & black for neutral. the bus bar support insulator made of non deteriorating, vermin proof, non hygroscopic materials such as smc / dmc. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a copper ferule crimped to the wire. the panel will have ms angle stand in 50x50x5mm size. size of panel 1360 mm ( h ) x 760 mm ( w ) 300mm ( d ) .having mccb 63amp. 415v, 50hz 18 ka tpn of high breaking capacity, 1 no., power contactor 220v 32amp. 3 nos. ( with aux contact block ) , thermal overload protection relay 9 15 amp. 01 no., star delta timer 01 no., digital timer switch 01 no., motor protection relay ( under voltage / over voltage / under current / dry run / single phase preventer ) 8 22 amp. 1 no, capacitor unit ( 5 ) kvar 1 no., indicating lights ryb 6 nos., on off 1 set, amp. meter digital 0 50a size 96 x 96 mm 1 no., volt meter ( digital type ) 0 500v size 96 x 96mm 1 no, controls mcb tpn 32 amp. 1 no., mcb sp 32 amp. 1 no., amp. & volt meter selector switches 1 set, ( auto manual reset, 2co contact ) 1 no. change over switch 1 no., terminal block 6 way 1 no., make of accessories: mccb / mcb: l&t / siemens / havells, power contactor: l&t / siemens, timer / relay: l&t / siemens, switchs / push button: l&t / siemens / havells, amp / volt meter: ae / l&t, indicating lights: havells / l&t 2 supply of pvc insulated pvc sheathed, copper conductor ( flexible ) flat cable, size 3 core x 6 sq mm , 1100 volts, conforming to is 694. make: havells / finolex / polycab / any djb approved 3 supply of lt power aluminum cable, solid xlpe, insulated pvc armoured 650 / 1100 volts, v grade as per is 7908 part i 1988 size 3.5 x 25 sq mm. make: havells / finolex / polycab / any djb approved 4 supply of kit kat board made out of wooden having 3 nos. 100 amp ( 415 volts re wireable ) kit kat of havells / standard / djb approved make. 5 insulating mats for electricial purpose confirming to is 1562 / 2000 of following sizes, 3mm thickness sor ( e&m ) item code 22.5.3 6 led ( tube light ) decorative ultra slim square profile led lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. lamp type order, 20 w led 6000 k, sor ( e&m ) item code 19.1.2 7 supply of 80mm dia. b class gi pipe length 3 mtr. with duly welded and threaded flange in both sides, complete with cutting of flange for cable and welded support in both flanges as per site requirement. make: jindal / parkash / surya / tata. 8 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and another end threaded of 80mm as per site requirement. 9 supply of 80mm dia. gi bend with both side flanges duly welded and threaded as per site requirement. 10 supply of m.s. clamp of ms strip duly hole for holding the pipe of 80mm dia. with nut bolts and washer. 11 supply of m.s. bore cover made out of ms plate suitable for 12 / 14 dia. bore complete with suitable hole for passing the 80mm dia. gi pipe 12 supply of nut bolts, washer of good quality as per requirement 13 supply of rubber packing sheet with 50 % neoprene ( 1.5 mm to 25 mm ) isi mark. ( payment will be made as per actual ) . sor ( e&m ) item code 22.6.1 14 fabrication / supply of venturi assembly 80 mm dia. with complete accessories as required at site. 15 supply of electrical dozing pump ( 4lph, 5.5 kg / cm, supply chemical grade tank of 100ltrs with nrv, foot valve with nrv, injector valve and tube ( pipe ) etc make: clormax / milton roy 16 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm.frls pvc insulated copper conductor single core cable etc. asrequired. sor ( e&m ) item code 31.8.3 17 workmanship charges for lowering the submersible pump set one no. in new bore well, fixing / erection / installation of e&m equipment, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e., eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the tube well will be commissioned on automation mode and timing to be set as per direction of engineer in charge. the all sundry items which are useful & necessary for operation of tube well in automation mode shall be deemed to have been included, whether such items are especially in specification or not. ( deep well submersible pump set and rccb provided by the department ) ...
39172500 improvement to bakkarwala housing complex. sub head construction / installation of one no. bore well / tube well at bakkarwala housing complex....
39119267 bids are invited for maintenance of various sports complexes. s.h: re development of existing bore well i / c providing and replacement of submersible pump set with accessories at qutab golf course / dda....
38896960 provision of 33 kv receiving stn at af station palam, new delhi. 1 supply laying jointingtesting and commissioning of 33 kv ( e ) grade of size 185 sqmm 3 core ( heavy duty ) with stranded compacted circular aluminum conductor, conductor screened with extruded semi conducting compound, xlpe insulated, insulationscreened with extruded semi conducting compound in combination with copper tape, cores laid up, inner sheath of thermoplastic tape, pvc bedded, galvanized steel striparmoured and over allfrls pvc sheated conforming tois 7098, part ii with latest amendmentslaid in cable ducts / trays / trenches / encased in gi pipes / rcc / dwc hdpe pipes complete all as specified and directed. 2 note for item no 1 ( i ) each cable drum not less than 500 mtr length ( ii ) the contractor will be responsible for taking permission from appropriate authority i.e. nhai / igl / cantt board or other units , if needed for the above said cable work necessary payments for work clearence / deposit chargesfor appropriate authorityto be incuded in the rate quoted above ( iii ) manual excavation has be carried out at the places of services such as of near existing ht / lt cables, ofc / telecom cables , water / gas pipe / sewage pipe lines, area drinages and contractor shall be responsible for rectification of damages immediately on priority to the damages of servicesoccured during exection of the cable / earth work. 3 supply, jointing and testing of end termination joint outdoor type heatshrinkble type complete with jointing material and accessories suitable for 33 kv ( e ) xlpe armoured aluminium conductor cable of size 185 sqmm 3 core complete all as specified and directed. 4 supply, jointing and testing of end termination joint indoor type for 33 kv gis panel touch proof type complete with jointing material and accessories suitable for 33 kv ( e ) xlpe armoured aluminium conductor cable of size 185 sqmm 3 core complete all as specified and directed. 5 supply, jointing and testing of straight through joint outdoor type heatshrinkble type complete with jointing material and accessories suitable for 33 kv ( e ) xlpe armoured aluminium conductor cable of size 185 sqmm 3 core complete all as specified and directed. 6 supplying, installing, testing and commissioning of 33kv, 630a, 25ka / 3 sec, iac, aflr, gas insulated type vcb panel making arrangement ip 4x indoor suitable, floor mounted, complying to iec 62271 200 for design, manufacturing and type tested, including internal arc for operator safety ( iac 26.3ka / 1 sec ) , having 02 x incomming +01 bus coupler+with 01 bus raiser+02 out goingall inside gas insulated ip65 ( partition class : partition of metal ) ss 304 grade ss tank ( 2.5 mm thickness ) , flush front mechanism having lockable access door with mounted bay protection and control scheme, including leds, mimic etc. as prescribed below , also scada complying to iec 61850 : 7 ( i ) rated voltage / maximum operating voltage 36 kv, ( ii ) rated power frquency withstand voltage 70 kv, ( iii ) rated lighting impulse withstand voltage 170 kv, ( iv ) rated frequency 50 hz, ( v ) rated short circuit making current 80 ka, ( vi ) rated short time withstand current 31.5 ka, ( vii ) rated duration of short circuit 3 sec, ( viii ) rated opening time = 45 m sec, ( ix ) rated break time = 60 m sec, ( x ) rated auxiliary voltage 110 v dc. ( xi ) gis vaccum interruter main numerical relays & meters must be same make for better life cycle optimization. ( xii ) each vcb shall 02 nos tripping coil. 8 ( a ) 02 x incomer 33 kv gis panel, each comprising of : 9 ( i ) 33 kv, 630 amp, 25ka / 3 sec, draw out vacuum circuit breaker as per iec 62271 100 with roll on floor type vacuum circuit breaker having 03 nos. vacuum bottles of same make as of circuit breaker and panel, motorized spring charging mechanism ( 230vac ) with integral spring charging handle for manual charging, associated push buttons, anti pumping feature, and associated shunt trip / close coils ( 110v dc ) . 10 ( ii ) current transformers 33 kv 100 / 1 1 amp, core1: class 0.5, 10va, core2: class ps x set of 03nos per breaker 11 ( iii ) potential transformers, draw out type for easy maintenance, 33kv / rt3:110v / rt3, 50va, cl.0.5 with associated gun type hrc fuses and mcbs for ht / lt isolation set of 03 nos. 12 ( a ) transient / intermittent earth fault protection ( b ) phase discontinuity protection ( c ) aux. protections incl. trip circuit supervision, circuit breaker failure protection, master trip etc. ( iv ) main, numerical, drawout protection relay ( line differential ) with large lcd displaying mimic bay for on / off control and monitoring of feeder parameters listed below and built in disturbance recorder cycle. the relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. breaker on, off, spring.charged, disconnector on, off, earth, line current / line voltage, trip circuit healthy, gas pressure low in breaker chamber, gas pressure low in busbar chamber, ac supply fail, local remote switchthe relay shall have built in back lit lcd screen to show single line diagram and other relevant parameters. 13 the relay shall be communicable on iec 61850 goose platform over double / redundant rj 45 / usb / fo port, having required protection functions including ( a ) line differential with high set and low set ( stabilized ) with second harmonic restraint to bypass transformer inrush. the scheme will be implemented using single mode fibre optic protection communication link between local and remote relay. suitable blocking arrangement shall be available to prevent nuisance tripping due to loss of connection, ( b ) over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively, ( c ) transient / intermittent earth fault protection, ( d ) phase discontinuity protection, ( e ) synchro check between incomer 01 and incomer 02 14 ( v ) flush mounted aux. protection relays incl. ( a ) trip circuit supervision relay, ( b ) master trip relay, ( c ) sf6 gas pressure low, ( d ) tcn ( e ) dcf ( f ) self supervision ( g ) sf 6 gas pressure low. ( vi ) metering equipment incl. 01 x digital voltmeter ( acc.cl.0.5 ) , 01 x digital ammeter ( acc.cl.0.5 ) , 01 x tri vector meter ( acc.cl.0.5 ) . 01no. multi function meter ( acc.cl.0.5 ) shall be provided with lcd display for measuring current, voltage, power, power factor and energy parameters, total harmonic distortion and max. demand indication, same shall be communicable on modbus via rs485 port ( vii ) led indications breaker on / off / trip / spring charged, r y b, disconnector on / off / earth, dc available, ac supply fail 15 ( viii ) 16 window annunciator with hooter to indicate following alarms : ( a ) sf6 gas pressure low ( busbar compartment ) , ( b ) sf6 gas pressure low ( breaker compartment ) , ( c ) dc fail, ( d ) master trip, ( e ) trip circuit failure, ( f ) inter tripping fault, ( g ) vacuum failure ( current flowing even after cb open ) , ( h ) ef & oc. the annunciator will be complete with required acknowledge / test buttons as required ( ix ) control equipment incl. 01 x tnc switch for cb on / off, 01 x local remote selector switch, push button for disconnector on / off, mcbs for ac / dc isolation as required 16 ( x ) other accessories incl. space heater with thermostat for lv panel and cable chamber, 3 pin socket with switch, cfl lamp. ( xi ) suitable terminal arrangement along with light interface unit, patch cord and associated port for spliced connection with external armoured fibre optic cable shall be provided for achieving pilot wire ( ofc ) connection ( line differential ) . 17 ( b ) 01 x bus coupler 33 kv gis panel ( i ) 33 kv, 630 amp, 25 ka / 3 sec, draw out vacuum circuit breaker as per iec 62271 100with roll on floor type vacuum circuit breaker having 03nos. vacuum bottles of same make as of circuit breaker and panel, motorized spring charging mechanism ( 230vac ) with integral spring charging handle for manual charging, associated push buttons, anti pumping feature, and associated shunt trip / close coils ( 110v dc ) . ( ii ) current transformers 33 kv 100 / 1 1 amp, core1: class 0.5, 10va, core2: class ps x set of 03 nos per breaker ( iii ) main protection relay shall be a numerical drawout ied relay ( should be gis manufacturers own make ) communicable on iec 61850 goose platform over double / redundant rj 45 / usb / fo port and hsr complaint with programmable min 14 digital input, min 10 digital outputs, 11 front led , large dynamic display , microprocessor based protection scheme for detecting, indicating and tripping the breaker on various faults like ( a ) over current+ earth fault protection for ht / lt side. the relay shall have complete bay control features incl. large lcd display for displaying feeder sld ( position indication ) , integrated on / off control function, three phase current measurement, disturbance recorder, event log and fault record with non volatile memory, self supervision.the relay shall have sufficient binary inputs and outputs to receive and issue external commands as listed separately. however more di & do may be provided in order to fulfill the scheme requirement for scada compatibilty. 18 the relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. breaker on / off / spring.chrgd, line current, sf6 gas pressure low ( busbar compartment ) , sf6 gas pressure low ( breaker compartment ) , master trip, trip circuit failure ( from tcs relay ) , vacuum failure ( current flowing even after cb open ) and display locally on a built in back lit lcd screen as a single line diagram with parameters as advised ( i ) manometer in each gas chamber. 19 ( ii ) led indications breaker on / off / trip / spring charged, r y b, disconnector on / off / earth, dc available ( iii ) 16 window annunciator with ackn / test / reset push button and hooter to indicate following alarms : ( a ) sf6 gas pressure low ( busbar compartment ) , ( b ) sf6 gas pressure low ( breaker compartment ) , ( c ) local master trip, ( d ) trip circuit failure, ( e ) vacuum failure ( current flowing even after cb open ) ( iv ) control equipment incl. 01 x tnc switch, mcbs for ac / dc isolation as required ( v ) other accessories incl. space heater with thermostat for lv panel and cable chamber, 3 pin socket with switch, led lamp ( vi ) soft ware for relay and cable. ( vii ) panel shall be offered with digital ammeter and selector switch ( viii ) the connection between bus coupler and riser must be inside gas. ( ix ) vaccuum interrupter and gis panel should be of same make. 20 ( c ) 02 nos. outgoing 33kv, 630a, 25 ka vacuum circuit breaker arrangement having motorized spring charging ( aux: 230vac ) , and continuous duty tripping / closing ( aux: 110vdc ) with bottom cable entry each comprising of ( i ) current transformers 33 kv 100 50 / 1 1 amp, core1: class 0.5, 10va, core2: class ps x set of 03nos. 21 ( ii ) main protection relay shall be a numerical drawout ied relay ( line differential ) communicable on iec 61850 goose platform over double / redundant rj 45 / usb / fo port, microprocessor based protection scheme for detecting, indicating and tripping the breaker on various faults like ( a ) line differential +over current+ earth fault protection for ht / lt side. the relay shall have complete bay control features incl. large lcd display for displaying feeder sld ( position indication ) , integrated on / off control function, three phase current measurement, disturbance recorder cycle, event log and fault record with non volatile memory, self supervision.the relay shall have sufficient binary inputs and outputs to receive and issue external commands as listed below : 22 the relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. breaker on / off / spring.chrgd, line current, sf6 gas pressure low ( breaker compartment ) , master trip, trip circuit failure ( from tcs relay ) , vacuum failure ( current flowing even after cb open ) and display locally on a built in back lit lcd screen as a single line diagram with parameters as advised ( iii ) metering equipment incl. 01 x digital ammeter ( acc.cl.0.5 ) , 01no. multi function meter ( acc.cl.0.5 ) shall be provided with lcd display for measuring current, voltage, power, power factor and energy parameters, total harmonic distortion and max. demand indication, same shall be communicable on modbus via rs485 port 23 ( iv ) led indications breaker on / off / trip / spring charged, r y b, disconnector on / off / earth, dc available ( v ) 16 window annunciator with ackn / test / reset push button and hooter to indicate following alarms : ( a ) sf6 gas pressure low ( busbar compartment ) , ( b ) sf6 gas pressure low ( breaker compartment ) , ( c ) local master trip, ( d ) trip circuit failure, ( e ) ef & oc ( f ) dc fail. ( vi ) control equipment incl. 01 x tnc switch, mcbs for ac / dc isolation as required ( vii ) line feeder shall have line differential protection inbuilt in the relay. transformer feeder shall have transformer differential protection in built in relay. ( viii ) each gas filled compartment shall have manometer. ( ix ) aux relay for wti, oti, bucholz alam & trip ( only for outgoing transformer feeder ) ( x ) self powered wirelwss thermal sensor to be provided on cable termination. sensor shall be supplied with necesary software / hardware to communicate with existing scada system. ( xi ) quoted rate shall deemed to inclusive of sitc of gis oem recommende touch proof termination kit suitable for gis panel. 24 dismantilling of existing 33 kv , 1250 amp gis panel ( abb ) from nsb ii sub stn carefully and shifting to shankar vihar substation including erection, testing, commissioning of the panel with existing gis panel in all respect i.e. cable termination kit supply , installation, commissionig , testing , calibration properly with existing 33 kv gis panel scheme wiring addition alteration etc for smooth execution and coupling with the help of abbs service team. complete all as directed and specified.note: ( i ) all rates quoted shall be include the modification of all technical / software / relay configuration to existing 33 kv gis panel calibration with existing system to the up system and down stream grids for discrimination chat / tripping against faults / over currents / earth faults / ofc based differential protection etc. ( ii ) rate quoted include the cost of necessary modification to the existing floor / cable trenches / civil work for installation of 33 kv gis panel 25 supply, installation, commissioning , design, engineering, manufacture, inspection, painting andtesting complete with all accessories of transformer of capacity 2.5 mva step down, outdoor floor mounted, double copper wound, 3 phase, 50 hz, ac, including all standard acessories as per latestis , oilimmersed, knan ( natural ester ) confirming to is 2026, most economical losses external cooling tubes / radiator cores type having no voltage ratio 33000 / 11000 volts, impedance % of 6.25 ( corresponding to principal tapping ) winding delta connecting on primary side ( hv side ) and star connected on secondary side ( lv side ) in accordance with vector symbol dyn11 ( vector group ) with neutral brought out on lv side and looping on hv side for continious output so as to alter / vary secondary voltage by ( + ) 5 to ( ) 15% in 16 equal steps of 1.25% to be changed by means of ( oltc ) on load tap changerof make ctr / olg with local / remote opertion features along with rtccpanel with avr relayfor auto / manual operation, cable end boxwith rated copper bus bars / bimatallic connectors shall be provided for the transformer on both ht and lt side for connecting 33 kv ht 3 core cable of size 185 sqmm on ht side and single core six runs of 300 sqmm 11kv ht cable on lt side. avr should be scada compatiabilty and hv / lv orientation 180 degree 26 transformer shall be of boltless core design. transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade, crgo with m4 grade or better, perfectly insulated and clamped to minimize noise and vibrations, core shall be purchased directly from manufacturer of core or from their accredited marketing network and not through any agent. before placing order for procurement of transformer, the contractor shall submit the credentials in respect of the manufacturer ofcore and transformer shall be procured only after approval from ge in respect of name of manufacturer of transformer as well as manufacturer of core. the limit of termperature rise after continous full load runs as specified in is / iec 60076 shall be suitably adjusted to suit the ambient temperature of maximum 50 degree celsius prevailing at site all as specified and directed including having following characteristics complete all as specified and directed. 27 the transformer shall confirm to the latest edition of applicable standard as follows : ( i ) is 2026, for tests and tolerance of guarnteed particulars, ( ii ) is 3639 for fitting and accessories ( iii ) is 2099 for bushing >1000v ( iv ) is 7421 for bushing <1000v ( v ) is 1271 for electrical insulation classified by thermal stability 28 ( a ) hv / lv winding electrolytic copper 99.9% purity 29 ( b ) insulation levelkvp ( i ) hv 170 ( ii ) lv 70 30 ( c ) insulation level ( power frequency with stand kvrms ) ( i ) hv 75 ( ii ) lv 28 31 ( d ) temperature raise for the transformer should be 50 / 55 deg.c ( oil / winding temp ) at av. ambient temperature of 50c ( e ) noise level for offered transformer will be as per nema tr1 only ( f ) over loading of the transformer should be of as per is 6600 only ( g ) transformer shall be of class h insulation ( h ) primary painting of zinc phosphate. ( i ) tank pressure, vaccum witstand capability & minimum clearances should be as per cbip manual. ( j ) neutral ct 150 / 1 ps class to be provided 32 % efficiency at 75deg c / unity p.fa ) at 100% load 98.87b ) at 75% load 99.07c ) at 50% load 99.23% regulation at full loada ) at unity pf 1.19b ) at 0.8 pf 4.60 33 note: ( i ) rate quoted includes the cost of transformer , rcc baffel wall as per electricity safety rule from gl with proper earth work between the both transformers, rcc foundation designed as per the oem recommendation based on the soil conditions of the delhi canttaf muesuim site ( ii ) rate quoted includes the cost of necessary power / control cables for operation of oltc, prv limit switches , wti , oti , double floatbucholz relayfrom rtcc panel in side substation buildingto transformer ( iii ) transformer shall be brought site only after approval of gtp drawings and only after completion of installation of 33kv gis panels and laying of 33kv cables i.e after completion of 50% of the work at siteto avoid ideal laying / ingress of moisture / corrossionto transformer at site which detoriates the life / warranty and service of the transformer ( iv ) testing & commissioning of transformer shall be carried out in the presence of oem at site. ( v ) oem of power transformer must have in house nabl accredited lab. 34 supplying, installing, testing and commissioning of indoor arc flash protected draw out with roll on floor type gis panel , rated for 11kv, 630 amp, 25ka / 3 sec, comprising of 02 x incomming +01 bus coupler+01 bus raiser+02 out going vcb panels confirming to iec 62271 200, and is 13118, accessibility class lsc2b pm class, comprising of 630 amp, continuous ratedinsulated copperbusbarsand droppers in all bus / breaker / adaptor and cable chambers , 02 nos. rack in rack out handles, structure made from aluzinc / gi / powder coated crcasheets to prevent corrosion and rusting.the complete panel incl. ht and lt chamber with frls wiring and acessoriesshall be manufactured by approved oem at its own mancufacturing in house facility, and same will be verified via stage / final inspection. system house integrator / channel partner products are not accepted .the offered panel shall be type tested for internal arc 25 ka for 1 sec with aflr classification make of the vcb, panel, relay and meters shall be of the same make / oem 35 ( a ) 02 x incomer panel, each comprising of : ( i ) 11kv, 630amp, 25ka / 3 sec, draw out vacuum circuit breaker as per iec 62271 100. vacuum circuit breaker having 03nos. vacuum bottles of same make as of circuit breaker and panel, motorized spring charging mechanism ( 230vac ) with integral spring charging handle for manual charging, associated push buttons, anti pumping feature, and associated shunt trip / close coils ( 110vdc ) . 36 ( ii ) current transformers 11kv, 300 150 / 1 1 1, core3: class 5p10, 5va, core2: class 0.5, 5va set of 03nos. ( for measuring, relaying and transformer differential ) core 1 :ps for ref ( iii ) potential transformer ( applicable for incommer as line pt ) :floor rolled / cb trolley mounted drawnout type 11kv / 110v / 110v, core 1: 0.5 , 20 va core2: 3p 20 va 04 pt must not be panel top mounted. 37 ( iv ) mainprotection relay shall be numerical ied relay confirming to iec60255, microprocessor based protection scheme for tripping the breaker on various faults like ( a ) over current or earth fault in any of the three phases, ( b ) circuit breaker failure alarm, 38 ( c ) interpanel tripping / blocking signals via goose based peer to peer communication, on iec61850 protocol. ( d ) integrted arc flash protection with current and light sensingthe relay shall be communicable on iec 61850 goose platform over double / redundant rj 45 / usb / fo port, and fully integrated with the feeder, internally capturing feeder statuses incl. various status, line current, breaker on / off / spring.chrgd, trip circuit failure ( from tcs relay ) , local remote etc. and display locally on a built in back lit lcd screen with mimic as a single line diagram with current measurements and suitably labelled status leds. ( e ) over and under voltage & ref protection shall be given for outgoing feederrelay setting should be possible through inbuilt software or through addtional software supplied by the relay manufacturer. 39 ( iv ) metering equipment including: ( a ) 01 x digital voltmeter ( acc.cl.0.5 ) , 01 x digital ammeter ( acc.cl.0.5 ) , ( b ) 01no. multi function meter ( acc.cl.0.5 ) shall be provided with lcd display for measuring current, voltage, power, power factor and energy parameters, total harmonic distortion and max. demand indication, same shall be communicable on modbus via rs485 port. 40 ( v ) led indications ( a ) breaker on / off / trip / spring charged, ( b ) trip circuit healthy 41 ( vi ) 08 window annunciator with hooter to indicate following alarms : ( a ) oc trip, ( b ) ef trip ( c ) trip circuit failure, ( d ) inter tripping fault, the annunciator will be complete with required acknowledge / test buttons as required 42 ( vii ) all multi function meters shall be connected in a modbus loop terminating into 01 no. modbus to tcp / ip converter to be provided for sending data to scada console via networking switch. 43 ( viii ) control equipment incl. ( a ) 01 x tnc switch, ( b ) 01 x emergency trip push button, ( c ) 01 x local / remote switch, ( d ) mcbs for ac / dc isolation ( e ) heater switch with thermostat 01no. ( f ) 3 pin socket with on / off switch 01no. ( g ) led lamp with on / off switch 01no. 44 ( ix ) flush mounted auxillary protection relays incl. ( a ) trip circuit supervision relay, ( b ) master trip relay, 45 ( b ) 01 x bus coupler panel with raiser, each comprising of : ( i ) 11kv, 630 amp, 25ka / 3 sec, draw out vacuum circuit breaker as per iec 62271 100with roll on floor type vacuum circuit breaker having 03nos. vacuum bottles of same make as of circuit breaker and panel, motorized spring charging mechanism ( 230vac ) with integral spring charging handle for manual charging, associated push buttons, anti pumping feature, and associated shunt trip / close coils ( 110v dc ) . 46 ( ii ) current transformers 11kv, 300 150 / 1 1 1, core3: class 5p10, 5va, core2: class 0.5, 5va set of 03nos. ( for measuring, relaying and transformer differential ) core 1 :ps for ref 47 ( iii ) main protection relay shall be numerical ied relay confirming to iec60255, having 04pt inputs with microprocessor based protection scheme for tripping the breaker on various faults like ( a ) synchronism and energizing check before bus coupler closing to prevent un syncronized mixing of supplies ( b ) circuit breaker failure alarm. ( c ) circuit breaker failures and interpanel tripping / blocking signals via goose based peer to peer communication, on iec61850 protocol. the relay shall be fully integrated with the feeder, internally capturing feeder statuses incl. various status, bus voltage and display the same locally on a built in back lit lcd screen with mimic as a single line diagram with power & frequency measurements and suitably labelled status leds.relay setting should be possible through inbuilt software or through addtional software supplied by the relay manufacturer. 48 ( iv ) led indications ( a ) breaker on / off / trip / spring charged ( b ) trip circuit healthy 49 ( v ) control equipment incl. : ( a ) 01 x tnc switch, ( b ) 01 x local / remote switch, ( c ) 01 x emergency trip push button, ( d ) mcbs for ac ( e ) mcbs for dc ( f ) heater switch with thermostat 01 no. ( g ) 3 pin socket with on / off switch 01 no. ( h ) led lamp with on / off switch 01 no. 50 ( vi ) flush mounted auxillary protection relays incl. ( a ) trip circuit supervision relay, ( b ) master trip relay, 51 ( vii ) 08 window annunciator with hooter to indicate following alarms : ( a ) trip circuit failure, ( b ) inter tripping fault, ( c ) synchro check. ( d ) pt fuse failurethe annunciator will be complete with required acknowledge / test buttons as required 52 ( c ) 02 x outgoing panel, each comprising of : ( i ) 11kv, 630amp, 25ka / 3 sec, draw out vacuum circuit breaker as per iec 62271 100. vacuum circuit breaker having 03nos. vacuum bottles of same make as of circuit breaker and panel, motorized spring charging mechanism ( 230vac ) with integral spring charging handle for manual charging, associated push buttons, anti pumping feature, and associated shunt trip / close coils ( 110 v dc ) . 53 ( ii ) current transformers 11kv, 300 150 / 1 1 1, core3: class 5p10, 5va, core2: class 0.5, 5va set of 03nos. ( for measuring, relaying and transformer differential ) core 1 :ps for ref 54 ( iii ) main protection relay shall be numerical ied relay confirming to iec60255, having 04ct inputs with microprocessor based protection scheme for tripping the breaker on various faults like ( a ) over current or earth fault in any of the three phases, ( b ) circuit breaker failure alarm, ( c ) interpanel tripping / blocking signals via goose based peer to peer communication, on iec61850 protocol. ( d ) integrted arc flash protection with current and light sensing. ( e ) tranformer protection ( marshalling box and buchhloz relay ) .the relay shall be communicable on iec 61850 goose platform over rj 45 / usb / fo port, and fully integrated with the feeder, internally capturing feeder statuses incl. various status, line current, breaker on / off / spring.chrgd, trip circuit failure ( from tcs relay ) , local remote etc. and display locally on a built in back lit lcd screen with mimic as a single line diagram with current measurements and suitably labelled status leds.relay setting should be possible through inbuilt software or through addtional software supplied by the relay manufacturer. 55 ( iv ) metering equipment including: ( a ) 01 x digital voltmeter ( acc.cl.0.5 ) , 01 x digital ammeter ( acc.cl.0.5 ) , ( b ) 01no. multi function meter ( acc.cl.0.5 ) shall be provided with lcd display for measuring current, voltage, power, power factor and energy parameters, total harmonic distortion and max. demand indication, same shall be communicable on modbus via rs485 port. 56 ( v ) led indications ( a ) breaker on / off / trip / spring charged, ( b ) trip circuit healthy 57 ( vi ) 08 window annunciator with hooter to indicate following alarms : ( a ) oc trip, ( b ) ef trip ( c ) trip circuit failure, ( d ) inter tripping fault, the annunciator will be complete with required acknowledge / test buttons as required 58 ( vii ) control equipment incl. ( a ) 01 x tnc switch, ( b ) 01 x emergency trip push button, ( c ) 01 x local / remote switch, ( d ) mcbs for ac / dc isolation ( e ) heater switch with thermostat 01no. ( f ) 3 pin socket with on / off switch 01no. ( g ) ledlamp with on / off switch 01no. 59 ( viii ) flush mounted auxillary protection relays incl. ( a ) trip circuit supervision relay, ( b ) master trip relay, 60 note for item 08 ( i ) cost of construction of foundation as per manufacturer design, including foundation frame ( supplied by oem ) , channels etc. for ht panel as required at site are deemed to be included in the quoted rate. ( ii ) each vcb panel being floor mounted, air insulated, fully compartmentalizeds the oem shall supervise and certify the commissioning / charging of equipment. ( iii ) foundation frames shall be inclusive in the scope of supply of oem. 61 ( iv ) all multi function meters shall be connected in a modbus loop terminating into 01 no. modbus to tcp / ip converter to be provided for sending data to scada console via networking switch. 62 ( v ) necessary cat 6 and modbus cabling from panel to rtu panel shall be provided by the contractor with in this scope only. 63 ( vii ) all incomers and buscouplers will have suitable schemes in place to prevent mixing of un syncronized supplies using line / buspt signals. any such attempt will be reported by a suitable alarm. this facility should be implemented over soft logic, and can be disabled by authorized personnel without requiring any on site re wiring. ( viii ) all outgoing vcbs will have inter tripping logic in place to ensure that incomer breaker immediately trips in case of failure of opening of outgoing vcb experiencing feeder fault. special and dedicated alarm shall be in place to issued the user. this facility should be implemented over soft logic, and can be disabled by authorized personnel without requiring any on site re wiring. ( ix ) self powered wirelwss thermal sensor to be provided on cable termination. sensor shall be supplied with necesary software / hardware to communicate with existing scada system. 64 supply laying jointing commissioning and testing of xlpe insulated screened, pvc bedded, galvanized steel strip / wire armoured electric power cable frls pvc sheated ( heavy duty ) with multistranded aluminum conductors 300 sqmm single core 11 kv ( e ) grade with stranded aluminium conductor complete laid in cableducts / trays / trenches / encased in gi pipes / rcc / dwc / hdpe pipes complete all as specified and directed. 65 s&f cable end jointing kit for 11 kv grade cable for indoor type termination heat shrinkable joint complete with jointing material and accessoies suitable for single core xlpe armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed. 66 m&l for boring of holes on any type of soil of size 250 mm dia, under road / pavement / hardstanding by trenchless technology using ultra sound technique and necessary machine including material and labour for hdpe pipe of 200 mm dia suitable for 04 kg / sqcm working pressure, wall thickness of pipe not less than 6.5 mm for 33 kv cable complete all as specified and directed. 67 note: for item no 11 ( i ) the contractor will be responsible for taking permission from appropriate authority i.e. nhai / igl or other units , if needed, for above said work. ( ii ) depth of trench less shall not less than 2 mtr from ground level unless other wise specifed due to site requirement and contractor has to maintain the depth of trenchless up to 4 mts from ground level if required as per site conditionsall rates quoted shall be demeed to be included to maintain the trench less depts as directed during exection to avoid damages to the existing services ( iii ) the cost quoted is deemed to be inculded for repiars / rectification for damages done to the existing elecrtical / comminication and water supply system / sewage systemduring execution of work ( iv ) hdpe pipe 40 mm dia ( item no 43 below ) is also passing along with 200 mm dia hdpe pipe through same bore. ( v ) no extra cost to be paid for passing of hdpe pipe. 68 m&l for excavation in trenches, n exc 1.5m wide and n. exc 1.5 m in depth and getting outfor laying of htcable / ofc / grid mating etc exc 10 sq m on plan and getting out complete all as specified and directed. 69 all as per item no 12 ( here in before ) but in hard rocks. 70 s&f gi pipe ( light grade ) with necessary accessories / fittings for cable protections / pole for crossing of culverts / nallah / of size 200 mm dia complete all as specified and directed. 71 m&l for returing / filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and directed. 72 m&l for removing of excavated material n exc. 50m and depostiting where directed at a level n exc. 1.5m in soils complete all as specified and directed. 73 m & l forsand cushioning to underground pvc cable inclpunning down of sand layer all as specified and directed. note : for measurement purpose only punned sand shall be measured & paid. 74 supply & laying reinforced precast concrete cable cover class ehv type 1 with peak size 450 mm x230mmx50mm in trenches for protection to under ground cable complete all as specified and directed 75 supply & laying un reinforced precast concrete cable cover class hvp type 1 with peak size 300 mm x180mmx40mm in trenches for protection to under ground cable complete all as specified and directed 76 s&f screw bolts ( machine made ) with hexagonal or square heads at one end and screwed the other each screw to be fitted with one washers and one hexagonal or square nut length of bolts n.exc 5cm and dia of shank 10mm all as specified and directed. 77 m&l for cement concrete 1:3:6 type c 2 ( using20mm graded crushed stone aggregate ) as in foundation filling and mass concreteas in channel / drains complete all asspecified & directed. 78 excavation in post holes n.exc 0.5 cum each getting out, returning filling in and ramming earth in layers n.exc 25cm watering and removing surplus soil to a distance n.exc 50m and making good surface in soft / loose soil complete all as specified and directed. 79 s&f galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securingor tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc etc as directed ( each line wire to be measured ) incl taking down old wire etc complete all as specified and directed 80 supply only chain link ms galvanised fencing, any size or type etc complete all as specified and directed. 81 fixing only chain link fencing including line wires, any mesh , size and type to any type of standards , rails , straining bolts, etc. including provision of binding wire complete all as specified and directed. 82 m&l for two coats of synthetic enamel paint over a coat of primer incl preparation of new steel surfaces of any description over 10cm girth or width complete all as specified and directed. 83 s&f in ms work such as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.flat iron fillets ( for securing wire mesh etc. ) including all necessary drilling, bolting or riveting, etc and similar work conforming to fe 290 gde e 165 all as specified and directed. 84 s&f 12mm dia round tmt bars as in fencing, cut to length fixing with posts / fencing, bindingsecuring with clips etc all as specified and directed 85 m&l for preparation of new steel surfaces not.exc 10cm width or girth and applying two coats of synthetic enamel paint overa coat of red oxide primer, complete all as specified and directed. 86 supply and fix cable route indicator made of rcc ( nominal mix ) type bo 1:2:4 ( 12.5 mm graded stone aggregate ) with 8 mm tmt bar 1.5 m height x 60 cm wide x 10 mm thick tapered on top visible above ground duly painted with synthetic enamel paint of yellow colour base and letters with black paint. the description for writing for ht cable 33000 volts will be given by engr in charge complete all as specified and directed. 87 m&l for danger notice board of 1.6 mm thick mild steel, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with ms clamps, bolts and nuts of approved size for ht 25 x 20 cm size complete all as specified anddirected. 88 m&l for erection of steel tubular swan neck pole for security lights , type 410 sp 31, 9.0 mtr long painted with two coats of synthetic aluminium enamel paint over a coat of red oxide primer, making 03 nos radium strip on pole of size 150mm height from gl to pole height 1.0 mtr complete all as specified and as directed ( note: excavation, pcc work shall be measured and paid separately ) 89 m&l for complete fixing ofenergy efficientled street lights fittings of 90 watt capacity , 220 volt , 50 hz, ip 65 / 66pole mountedincluding pole box and connecting wire of 1.5 sqmm 3 core from pole box to fitting all as specified and directed. 90 m&l for pcc in foundation filling and mass concrete type c2 ( 1:3:6 ) using 40 mm graded aggregate complete all as specified and directed 91 m& l for pcc type b1 ( 1:2:4 ) using 20 mm graded stone aggregate for pole coping complete all as specified and directed 92 m&l for bore earthing in hard rock of 150 mm dia, depth 30 mtr below ground level using earth electrode 50 mm dia gi pipe medium grade duly drilled hole of 12 mm dia 115 cm c / c on both side of the pipe including lowering in bore well upto the depth of 29 mtr and one mtr above the ground level the pipe electrode should be filled around commercial salt charcoal dust / breeze and magnesium phosphate of 30 cm layer each upto the fiull length of pipe. the bore well should have 06 mtr of length 150mm dia ms pipe for protection of bore well welding of gi strip 50 x 6 mm on earth electrod gi pipe 50 mm dia upto the 20 mtr below ground level 15 mtr from the bore well to test point. necessary water connection by gi steel tubing light grade10 mm dia complete all as directed by engineer in charge. note : gi strip more than 30 mtr will be measured and paid separetely. 93 m&lfor laying , fixing of gi strip 50 x 6 mm with saddle and fixing screw etc complete all as specified and directed. 94 m&l for earthingwith copper plate electrode 600x600x3.15 mm thick buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 20x3mm ( up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron electric arc welding all joints all as specified and shown in electrical plate no 3 of ssr part i including necessary excavation and earth work in any type of soil pcc 1:3:6 type c1 chamber with pcc 1:2:4 type b1 40 mm thick cover with ms rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia medium grade for protection of earth electrode 20 mm dia for watering complete all as specified and directed and tested on completion complete all as specified and directed. 95 m&l for copper strip 20 x 3 mm with saddle and fixing screw etc complete all as specified and directed. 96 m&l for gravel filling of size n.exc 40 mm, deposited spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 97 s &f fire retardant / extinguishing electric insulated synthetic mat insulatica 2000 of 3.0mm thick + 10% confirming to bis : doc no et 02 ( 5440 ) dated 30 apr 2004, meeting requirement of is 3043, is 5216 ( part i, ii &ii ) , is 8437 and iec 479 pub i, tested for breakdiwn strength, tensile / elongation ageing properties, insulation resistance , effect of acid, alkaline, diesel and transformer oil leakage current test, fire test etc, having minimumwidth of 1000mm + 20mm including all allied materials such as pu resin, chemical bound ( haedener ) special pvc adhesive liquid primer etc of required quantity to complete the job as per site requirement of all voltages not exceeding 33 kv system without ht trolley movement. of size 2 x 1 mtr complete all as specified and directed. 98 supply, laying, jointing and testing of armoured optical fibre underground cable, 12 core ( fiber ) along with light interfacing unit laid in trenches / ducts / fixed on poles / walls, laid under / path or encased in hdpe pipe complete all as specified and directed. note : the cost of joints / splicing deemed to included in the quoted rate. 99 m&l high density polyethylene pipes ( duct for ofc ) of size 40 mm dia ( hdpe ) ofpressure rating 10 kg / cm2 laid in trenches / bore holes of road crossing / hard standing for laying of ofc complete all as specified and directed.. 100 m&l for splicing work of optical fibre cable of 6 / 12 core forend connection at fibre optic distribution box complete all as directed. 101 s&f patch cords having any type of connectors ( sc / lc / st / fc ) at both ends as per site requirement complete all as directed. 102 s&f ofc 12 liu port complete all as directed. 103 supply installation & commissioning of 110v / 30a scr controlled float cum boost battery charger unit including battery bank comprising 2 volts / 100 ah cells 55 nos sealed maintenance free battery.the cccv battery charger consisting of copper wound, air cooled transformer, 01 set single phase full wave bridge rectifier consisting of diodes and scrs, liberally rated mounted on heat sink and complete with resistor / condenser network for surge suppression.during auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 set of solid state constant potential controller to stabilize the dc output voltage of the float cum boost charger, 01 no electronic controller, dcdigital ammeter, dc digitalvoltmeter, potentiometer, dc, mcb for reverse battery protection. the charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. float cum boost battery charger and dc distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness, louvers for ventilation, gland plate will be provided for cable entry from bottom. the battery charger shall be divided into two compartments.the upper compartment shall house the battery charger & dcdb with all necessary controls. the lower compartment shall be suitable for housing the batteries. tech specification shall be as under: 104 ( a ) input working voltage 180 270 volts ( b ) nominal input voltage 230 v , ac , 50 hz, 1 ( c ) on load input power factor > 0.8 ( d ) on load unit watt efficiencies > 80% ( e ) no load losses of complete charge < 10% ( f ) ripple contents on the load ( rms ) = 1% to 5% ( g ) overload 110% for 30 minutes and will give visual indication for over load condition. ( h ) boost charging 2.4 v / cell. ( j ) float charging 2.15 v / cell ( k ) float cum boost charging automatically changes from one state to another state as per battery condition and wiil give the visual indication for either float or boost based on charging mode. ( l ) reverse polarity no damage will be caused.a visual indication for reverse polarity will appear with an audio alarm. ( m ) short circuit mcb protection provided. 105 supply, installation of required equipments at airforce muesum, palam substation for hooking up 33kv & 11kv switchgears to shankar vihar ids subattion scada and integartion subsequently.tentetive equipments shall be as follows but not limited to:a. 1 nos. serial to tcp converter, rj11 / rj45 to serial converter for multifunction meter accessb. 1 nos. relay networking ethernet switches: ( loose supply ) to be mounted inside the 33kv or 11kv switchgear panel managed fast / gigabit ethernet 19’ switch each 20 fast ethernet ports, with single aux. supply.c. 1 nos. iec 61850 compliant i / o units for acquisition of substation miscellaneous signals from battery charger, ups etc. – i / o capability up to 24 i / od. equipment for rtcc control supported over modbus control along with tcp converter ( if required ) e. cat 6 cable for relay networking upto ethernet switches forsubstation as required.f. ofc cable and its termination from liu to ethernet switch g. intergartion of complete 33kv & 11kv switchgear and other substation equipments at shankar vihar ids substation scada. 106 supply and installation of co2 portable type fire extinguisher isi marked confirming to is:15683 of capacity 4.5 kg complete with delivery house horn, squeeze grip release valve, locking arrangement, operational manaul, braket with screws and sleeves complete all as specified and directed. 107 supply and installation of co2 wheel mountedtype fire extinguisher isi marked confirming to is:2878 :2004of capacity 9 kg complete with delivery house horn, squeeze grip release valve, locking arrangement, operational manual, braket with screws and sleeves complete all as specified and directed....
38806972 annual repair and maintenance of to vayu bhawan, new delhi during 2023 24 ( sh: p / f informatory sign board and buffing of air force crest and cleaning and chemical treatment of water supply tank and cleaning of sewerage & drainage system and redevelopment of existing bore well ) ...
38681850 renovation of enm equipments at sangam park tu in door type 7.5 to 10hp lt cubical type electrical panel board floor / wall mounted of welded construction of size 1370mm x 760mm x 460mm fabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i / c powder coating , vermin proof having following items. 1. mccb 63 amp, 4 pole 1no. 2. rccb / elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no 3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no 4. digital ampere meter 96mmx96mm square shape of 0 30 amp range 1no 5. digital voltmeter of 96mm x 96 mm square shape of 0–500 volt range with selector switch 1no 6. led indicating lamps with fitting ( a set of 3 lamps ) 1set 7. shunt capacitor of 5 kvar with three phase isolator 1no 8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage low voltage protection. 1no 9. programmable time switch ( i.e., ryb phase & facility to change over from automatic to manual & vice versa ) up to 10 h.p.1no 10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc. as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame. make: all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved. 2 supply of kit kat board made out of wooden having 3 nos. 100 amp ( 415 volts re wireable ) kit kat of havells / standard / djb approved make. 3 supply of pvc insulated pvc sheathed, copper flat submersible conductor ( flexible ) cable, size 3 core x 6 sq mm , 1100 volts, conforming to is 694 . make: havells / finolex / djb approved make 4 supply of energy saving & environment friendly, pressure die cast aluminum housing 45 watt led street luminaries. make: havells / bajaj / crompton / dib approved make 5 supply of 50mm dia. b class gi pipe length 3 mtr. with duly welded flange in both sides, complete with cutting of flange for cable and welded support in both flanges.make: jindal / parkash / surya / tata / tata / jindal hisar / jindal gaziabad / isi 6 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and other end threaded of 50mm dia. make: jindal hisar / jindal gaziabad / isi 7 supply of nut bolts, washer, spring of sizes as per site requirement. 8 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. djb sor 9 supplying and laying 25 mm x 5 mm g.i strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm. djb sor 10 workmanship charges for lowering the submersible pump set one no. in bore well, fixing / erection / installation of e&m equipments, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e. eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the all sundry items which are useful & necessary for operation of tube well shall be deemed to have been included, such items are especially in specification as per site requirement. be well in ac 18. ( re invite ) ...
38641981 re development of existing tube well bore well in the todapur farm at iari new delhi 12....
38591453 tender for drilling of 19 nos 150 mm diameter bore well at different wards of nagar palika dallirajhara....
38447389 re development of existing tube well bore well in the saraswati hostel at iari new delhi 12....
38373067 provision of re bore well at skv ghitorni, new delhi. ( school id 1720033, building id 17201201 and eor id 20211341 ) . ( civil plus electrical work ) ....
38199267 renovation of electrical and mechanical equipments at sangam park tube well in ac 18 1 in door type 7.5 to 10hp lt cubical type electrical panel board floor / wall mounted of welded construction of size 1370mm x 760mm x 460mm fabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i / c powder coating , vermin proof having following items. 1. mccb 63 amp, 4 pole 1no. 2. rccb / elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no 3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no 4. digital ampere meter 96mmx96mm square shape of 0 30 amp range 1no 5. digital voltmeter of 96mm x 96 mm square shape of 0–500 volt range with selector switch 1no 6. led indicating lamps with fitting ( a set of 3 lamps ) 1set 7. shunt capacitor of 5 kvar with three phase isolator 1no 8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage low voltage protection. 1no 9. programmable time switch ( i.e., ryb phase & facility to change over from automatic to manual & vice versa ) up to 10 h.p.1no 10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc. as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame. make: all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved. 2 supply of kit kat board made out of wooden having 3 nos. 100 amp ( 415 volts re wireable ) kit kat of havells / standard / djb approved make. 3 supply of pvc insulated pvc sheathed, copper flat submersible conductor ( flexible ) cable, size 3 core x 6 sq mm , 1100 volts, conforming to is 694 . make: havells / finolex / djb approved make 4 supply of energy saving & environment friendly, pressure die cast aluminum housing 45 watt led street luminaries. make: havells / bajaj / crompton / dib approved make 5 supply of 50mm dia. b class gi pipe length 3 mtr. with duly welded flange in both sides, complete with cutting of flange for cable and welded support in both flanges.make: jindal / parkash / surya / tata / tata / jindal hisar / jindal gaziabad / isi 6 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and other end threaded of 50mm dia. make: jindal hisar / jindal gaziabad / isi 7 supply of nut bolts, washer, spring of sizes as per site requirement. 8 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. djb sor 9 supplying and laying 25 mm x 5 mm g.i strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with g.i. nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of g.i. nut bolt & spring washer spaced at 50mm. djb sor 10 workmanship charges for lowering the submersible pump set one no. in bore well, fixing / erection / installation of e&m equipments, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e. eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the all sundry items which are useful & necessary for operation of tube well shall be deemed to have been included, such items are especially in specification as per site requirement....
38001338 bids are invited for title1 development of tube well in accordance with is 2800 ( part i ) and is 11189, to establish maximum rate of usable water yield without sand content ( beyond permissible limit ) , with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “v” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i / c disinfection of tube well, all complete, including hire &labour charges of air compressor, tools & accessories etc., all as per requirement and direction of engineer in charge. dsr 2021 title2 supplying and installation g i pipe b class size 50mm complete with suitable g i fittings etc as required. i / c rebate of old material. title3 lowering and lifting of existing 5 hp submersible pump set etc. complete as required. title4 supplying and drawing flat three core pvc insulated & pvc sheathed copper cable size 2.5 sq mm complete with connection testing etc as required i / c rebate of old material. title5 providing and fixing bore cap suitable for 150 mm dai bore well to protect the bore well complete with welding work, nut bolt, washer etc. as required i / c rebate of old material. title6 sitc of submersible pump set 5 hp 3 phase with 8 stage pump etc. as required i / c rebate of old material. title7 sitc direct on line submersible starter panel ( outdoor ) three phase max. operational current 9.52 ( a ) contactor 20 ( a ) over load relay 6 10 ( a ) etc. as required ( i / c less cost of replaced item ) . title8 supplying and replacement of following accessories in the existing borewell such as i / c rebate of old material ( a ) reducer 50 mm x 40 mm title9 supplying and replacement of following accessories in the existing borewell such as i / c rebate of old material ( b ) supporting clamp with nut bolts 40 mm title10 supplying and replacement of following accessories in the existing borewell such as i / c rebate of old material ( c ) c i flange 50 mm with rubber paking title11 supplying and replacement of following accessories in the existing borewell such as i / c rebate of old material ( d ) g i socket 50 mm title12 supplying and replacement of casing pipe 150mm b class thickness complete with cutting welding threading drilling etc as required i / c rebate of old material ....
37886428 tender for re development of existing tube well bore well in the saraswati hostel at iari new delhi 12....
37882663 supply installation testing commissioning of submersible pump set with all enm equipments for newly bored tube wells at t block okhla phase ii near mla office under tughlakabad constituency ac 52. 1 s/o. sub. p/set for deep bore wells (high head) of 7.5 hp with dynamically balanced motor, vibration free total enclosed motor fitted squirrel cage induction motor, water lubricated thrust bearing, fitted with s.s. impeller mounted on stainless steel shaft of following parameters having 2900 rpm, suitable to operate on 3 phase 415 volt 50 hz, a.c. supply., head in meters approx. – 144 82, discharge in lpm – 95 170., method of starting – star – delta, delivery size –50 mm, make: su/bs/djb approved, dsr 2.4.6 2 s/o hut type electrical feeder pillar/metal boardof welded construction ofsize 1370mm x 760mm x 460mm fabricated with suitable sizems angle iron with 16 swgm.s. sheet, havinghorizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double doorand s.s hinges along with double locking arrangement, having fabricatedms angle ironframe for mounting of switch gears such as rccb, mccb, ryb indicating lights, selector switch, ampere meter, volt meter and electrical energy meter etci/c painting having following items ;mccb 63 amp, 4 pole, breaking capacity at 415 v: 25 ka, adjustable thermal setting (70 100%) and fixed magnetic settings. confirms to iec: 60947 ii/is: 13947 ii, rccb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically in the event of earth leakage, sensitivity: 300 ma, confirms to iec: 61008 i/is: 12640 i, fully automatic star delta starter of 10hp, 3phase oil immersed type,ampere meter 96mmx96mm square shape of 0 30 amp range,voltmeter of 96mm x 96 mm square shape of 0 500 volt range with selector switch, led indicating lamps with fitting (a set of 3 lamps), shunt capacitor of 10 kvar mpp type with three phase isolator withsuitable banking ,panel should have motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage low voltage protection. time delay power on programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p., complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire &thimblingetc as required.the panel board shall be mounted on the base frame of 2 feet height made of 50x50x6mm angle iron frame. dsr 10.2.1, make: the entire insert used in panel must be of djb approved makes wherever applicable 3 s/o pvc insulated & pvc sheathed flat cable with plain copper conductor having 3 cores 4 sq. mm size for submersible motor. (each roll of 100 mtrs), make: havells/ fort gloster/ grandlay/ icl/ cci/ icc/ universal 4 s/o m.s. clamp of 600 mm length duly fabricated from 12.5 mm thick 75 mm wide m.s. plate for holding the pipe of 50 mm dia. 5 s/o of double flange g.i. column pipe 50 mm dia., medium class, each of 3mtrs long duly threaded on both ends, welded & fitted with g.i. flange on both ends welded with three nos. support strip at each end between flange and pipe, with two slots for sub cable in each flange. make of pipe: tata/jindal. 6 s/o tail piece of the medium class g.i. pipe 500 mm long with one end threaded as per outlet of pump & another end flanged as per size of g.i. pipe 50 mm dia. make of pipe: tata/jindal 7 s/o g.i.900 x 50 mm dia. bend having flange at both ends (heavy duty). 8 supply of ms full threaded nut bolts off sizes as per site requirement 9 supply of rubber packing for 50mm dia. flange( 3 mm thick) 10 supply of bore cover approx size 1’x1’ made out from 6mm thick m.s. sheet in 2 halves & a circular hole in centre 2 1/2” dia with locking arrangement by nuts & bolt 11 supply ci d/f non return valve of size 50 mm dia.,as per is 5312(part 1&2)pn 1.0 ci body, door/bronze to rubber rings/ss410 hinge pin construction make: ivc/kirloskar, dsr 4.9.2 12 installation of t/well by lowering of sub p/set with all allied above items.this includes installation and grouting of panel board with all electrical wiring & cabling at site.all tools & tackles i/c tripod chain pulley blocks etc. shall be arranged by the firm.this includes testing & commissioning of t/well on load at site i/c cartage, loading & unloading of material.it also includes trial run of 100 hrs operation successfully by the firm.all required civil work included in the scope of work. ...
37882586 supply installation testing commissioning of submersible pump set with all enm equipments for newly bored tube wells at x block okhla phase ii under tughlakabad constituency ac 52. 1 s/o. sub. p/set for deep bore wells (high head) of 7.5 hp with dynamically balanced motor, vibration free total enclosed motor fitted squirrel cage induction motor, water lubricated thrust bearing, fitted with s.s. impeller mounted on stainless steel shaft of following parameters having 2900 rpm, suitable to operate on 3 phase 415 volt 50 hz, a.c. supply., head in meters approx. – 144 82, discharge in lpm – 95 170., method of starting – star – delta, delivery size –50 mm, make: su/bs/djb approved, dsr 2.4.6 2 s/o hut type electrical feeder pillar/metal boardof welded construction ofsize 1370mm x 760mm x 460mm fabricated with suitable sizems angle iron with 16 swgm.s. sheet, havinghorizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double doorand s.s hinges along with double locking arrangement, having fabricatedms angle ironframe for mounting of switch gears such as rccb, mccb, ryb indicating lights, selector switch, ampere meter, volt meter and electrical energy meter etci/c painting having following items ;mccb 63 amp, 4 pole, breaking capacity at 415 v: 25 ka, adjustable thermal setting (70 100%) and fixed magnetic settings. confirms to iec: 60947 ii/is: 13947 ii, rccb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically in the event of earth leakage, sensitivity: 300 ma, confirms to iec: 61008 i/is: 12640 i, fully automatic star delta starter of 10hp, 3phase oil immersed type,ampere meter 96mmx96mm square shape of 0 30 amp range,voltmeter of 96mm x 96 mm square shape of 0 500 volt range with selector switch, led indicating lamps with fitting (a set of 3 lamps), shunt capacitor of 10 kvar mpp type with three phase isolator withsuitable banking ,panel should have motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage low voltage protection. time delay power on programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p., complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire &thimblingetc as required.the panel board shall be mounted on the base frame of 2 feet height made of 50x50x6mm angle iron frame. dsr 10.2.1, make: the entire insert used in panel must be of djb approved makes wherever applicable 3 s/o pvc insulated & pvc sheathed flat cable with plain copper conductor having 3 cores 4 sq. mm size for submersible motor. (each roll of 100 mtrs), make: havells/ fort gloster/ grandlay/ icl/ cci/ icc/ universal 4 s/o m.s. clamp of 600 mm length duly fabricated from 12.5 mm thick 75 mm wide m.s. plate for holding the pipe of 50 mm dia. 5 s/o of double flange g.i. column pipe 50 mm dia., medium class, each of 3mtrs long duly threaded on both ends, welded & fitted with g.i. flange on both ends welded with three nos. support strip at each end between flange and pipe, with two slots for sub cable in each flange. make of pipe: tata/jindal. 6 s/o tail piece of the medium class g.i. pipe 500 mm long with one end threaded as per outlet of pump & another end flanged as per size of g.i. pipe 50 mm dia. make of pipe: tata/jindal 7 s/o g.i.900 x 50 mm dia. bend having flange at both ends (heavy duty). 8 supply of ms full threaded nut bolts off sizes as per site requirement 9 supply of rubber packing for 50mm dia. flange( 3 mm thick) 10 supply of bore cover approx size 1’x1’ made out from 6mm thick m.s. sheet in 2 halves & a circular hole in centre 2 1/2” dia with locking arrangement by nuts & bolt 11 supply ci d/f non return valve of size 50 mm dia.,as per is 5312(part 1&2)pn 1.0 ci body, door/bronze to rubber rings/ss410 hinge pin construction make: ivc/kirloskar, dsr 4.9.2 12 installation of t/well by lowering of sub p/set with all allied above items.this includes installation and grouting of panel board with all electrical wiring & cabling at site.all tools & tackles i/c tripod chain pulley blocks etc. shall be arranged by the firm.this includes testing & commissioning of t/well on load at site i/c cartage, loading & unloading of material.it also includes trial run of 100 hrs operation successfully by the firm.all required civil work included in the scope of work. ...
37872114 re development of existing tube well bore well in the saraswati hostel at iari new delhi 12....
37597891 construction of 120 type ii flats at sector vii, pushp vihar, saket, new delhi. sub head:digging of bore well including erection of casing pipes, submersible pump, panel & all mechanical and electrical accessories at sec vii, pushp vihar, saket, new delhi....
37448808 construction of 120 type ii flats at sector vii, pushp vihar, saket, new delhi.sub head:digging of bore well including erection of casing pipes, submersible pump, panel & all mechanical and electrical accessories at sec vii, pushp vihar, saket, new delhi....
37359374 construction of 120 type ii flats at sector vii, pushp vihar, saket, new delhi sub head:digging of bore well including erection of casing pipes, submersible pump, panel & all mechanical and electrical accessories at sec vii, pushp vihar, saket, new delhi...
37179128 annual repair and maintenance of to vayu bhawan during 2023 24 ( sh: providing and fixing informatory sign board & buffing of air force crest and cleaning and chemical treatment of water supply tank & cleaning of sewerage & drainage system and redevelopment of existing bore well ) ...
37074175 supply, installation, testing and commissioning of electrical and mechanical equipment of tube well at mcd staff quarter in d 1 block nand nagri. ( re invite ) 1 supply of panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for operation of 10 15hp submersible pump set with automatic phase corrector, made of 2mm thick crca sheet for load bearing members, totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. each part of the fabricated panel will be strictly subjected to seven tank treatment. the various components, assemblies and sub equipment of the panel will be as per standard given in relevant is. the bus bar shall be aluminum rectangular cross section size 20 mm x5 mm strip per phase, rating 63 amp. the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. the bus bar will be covered with heat shrinkable pvc sleeve throughout in red, yellow & blue color to identify three phases & black for neutral. the bus bar support insulator made of non deteriorating, vermin proof, non hygroscopic materials such as smc/dmc. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a copper ferule crimped to the wire. the panel will have ms angle stand in 40x40x5mm size. size of panel 915 mm (h) x 600 mm (w) 250mm (d). having mccb 63amp. 415v, 50hz tpn of high breaking capacity, 1no., power contactor 220v 32amp. 3nos(with aux contact block), thermal overload protection relay 15 24 amp. 01 no., star delta timer 1no., digital timer switch 1 no., motor protection relay (under voltage/over voltage/under current/ dry run/ single phase preventer) 15 24amp. 1no, capacitor unit (5) kvar 1no., indicating lights ryb 6 nos., on off 1set, amp. meterdigitl0 50a size96x96mm 1no., volt meter (digital type) 0 500v size 96x96mm 1no, controls mcb tpn 32amp. 1no., mcb sp 32amp. 3no., amp. & volt meter selector switches 1set, (auto manual reset, 2co contact) 1no. change over switch 63 amp 1 no., terminal block 6 way 1 no., make of accessories: all mccb/mcb/contactor/timer/relay/lights/push button: l&t/siemens/havells.amp/volt meter/current transformer: ae/l&t/havells. 2 supply of pvc insulated pvc sheathed, copper conductor(flexible) cable, size 3 core x 6 sq mm ,1100 volts, conforming to is 694 .make: havells/finolex/polycab djb approved make 3 supply of 80mm dia. b class gi pipe length 3 mtr. with duly welded and threaded flange in both sides, complete with cutting of flange for cable and welded support in both flanges as per site requirement. make: jindal/ parkash/ surya/tata/jindal hisar/jindal ghaziabad. 4 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and another end threaded of 80mm as per site requirement. 5 supply of 80mm dia. gi bend with both side flanges duly welded and threaded as per site requirement. 6 supply of m.s. clamp of ms strip duly hole for holding the pipe of 80mm dia. with nut bolts and washer. 7 supply of m.s. bore cover made out of ms plate suitable for 10/12 dia. bore complete with suitable hole for passing the 80mm dia. gi pipe 8 supply of nut bolts, washer of good quality as per requirement 9 supply of rubber packing sheet with 50 % neoprene (1.5 mm to 25 mm) isi mark. (payment will be made as per actual). sor (e&m) 2022 item code 22.6.1 10 fabrication/ supply of venturi assembly 80 mm dia. with complete accessories as required at site. 11 supply of electrical dozing pump (4lph, 5.5 kg/cm, supply chemical grade tank of 100ltrs with nrv, foot valve with nrv, injector valve and tube (pipe) etc make: clormax /milton roy 12 36w led fixture with led lamp, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver. sor (e&m) 2022 item code 19.3.3 make: havells, philips,crompton 13 supply of 45w l.e.d light energy saving & environmental friendly long life versatile pressure die cast aluminum ip 66 roadway laminate with high power l.e. d as light source. sor (e&m) 2022 item code 19.10.5 make: havells/ bajaj/crompton/ phillips. 14 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required (d.s.r 2022 e&m code no1.8.3) group c 15 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2x2.5 sq.mm (d.s.r 2022 e&m code no 1.17.11) 16 supply and fixing if 32mm dia. 02 mtr. long g.i pipe (medium class) bracket for mounting of fluorescent/ hpmv/hpsv street light fitting on pole/ wall including bending the pipe to the required shape, 2 nos. 40mmx 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. dsr 2022, item code 12.34 17 workmanship charges for lowering the submersible pump set one no. in re developed bore well, fixing/erection/installation of e&m equipment, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e., eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the tube well will be commissioned on automation mode and timing to be set as per direction of engineer in charge. the all sundry items which are useful & necessary for operation of tube well in automation mode shall be deemed to have been included, whether such items are especially in specification or not. (deep well submersible pump set, insulating mat, sluice valve and nrv will be provided by the department) ...
37041475 repair and replacement of defective 3 hp submersible pump for existing bore well installed at equal opportunity cell, university of delhi....
36942578 supply, installation, testing and commissioning of electrical and mechanical equipment of tube well at mcd staff quarter in d 1 block nand nagri. 1 supply of panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for operation of 10 15hp submersible pump set with automatic phase corrector, made of 2mm thick crca sheet for load bearing members, totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. each part of the fabricated panel will be strictly subjected to seven tank treatment. the various components, assemblies and sub equipment of the panel will be as per standard given in relevant is. the bus bar shall be aluminum rectangular cross section size 20 mm x5 mm strip per phase, rating 63 amp. the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. the bus bar will be covered with heat shrinkable pvc sleeve throughout in red, yellow & blue color to identify three phases & black for neutral. the bus bar support insulator made of non deteriorating, vermin proof, non hygroscopic materials such as smc/dmc. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a copper ferule crimped to the wire. the panel will have ms angle stand in 40x40x5mm size. size of panel 915 mm (h) x 600 mm (w) 250mm (d). having mccb 63amp. 415v, 50hz tpn of high breaking capacity, 1no., power contactor 220v 32amp. 3nos(with aux contact block), thermal overload protection relay 15 24 amp. 01 no., star delta timer 1no., digital timer switch 1 no., motor protection relay (under voltage/over voltage/under current/ dry run/ single phase preventer) 15 24amp. 1no, capacitor unit (5) kvar 1no., indicating lights ryb 6 nos., on off 1set, amp. meterdigitl0 50a size96x96mm 1no., volt meter (digital type) 0 500v size 96x96mm 1no, controls mcb tpn 32amp. 1no., mcb sp 32amp. 3no., amp. & volt meter selector switches 1set, (auto manual reset, 2co contact) 1no. change over switch 63 amp 1 no., terminal block 6 way 1 no., make of accessories: all mccb/mcb/contactor/timer/relay/lights/push button: l&t/siemens/havells.amp/volt meter/current transformer: ae/l&t/havells. 2 supply of pvc insulated pvc sheathed, copper conductor(flexible) cable, size 3 core x 6 sq mm ,1100 volts, conforming to is 694 .make: havells/finolex/polycab djb approved make 3 supply of 80mm dia. b class gi pipe length 3 mtr. with duly welded and threaded flange in both sides, complete with cutting of flange for cable and welded support in both flanges as per site requirement. make: jindal/ parkash/ surya/tata/jindal hisar/jindal ghaziabad. 4 supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and another end threaded of 80mm as per site requirement. 5 supply of 80mm dia. gi bend with both side flanges duly welded and threaded as per site requirement. 6 supply of m.s. clamp of ms strip duly hole for holding the pipe of 80mm dia. with nut bolts and washer. 7 supply of m.s. bore cover made out of ms plate suitable for 10/12 dia. bore complete with suitable hole for passing the 80mm dia. gi pipe 8 supply of nut bolts, washer of good quality as per requirement 9 supply of rubber packing sheet with 50 % neoprene (1.5 mm to 25 mm) isi mark. (payment will be made as per actual). sor (e&m) 2022 item code 22.6.1 10 fabrication/ supply of venturi assembly 80 mm dia. with complete accessories as required at site. 11 supply of electrical dozing pump (4lph, 5.5 kg/cm, supply chemical grade tank of 100ltrs with nrv, foot valve with nrv, injector valve and tube (pipe) etc make: clormax /milton roy 12 36w led fixture with led lamp, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver. sor (e&m) 2022 item code 19.3.3 make: havells, philips,crompton 13 supply of 45w l.e.d light energy saving & environmental friendly long life versatile pressure die cast aluminum ip 66 roadway laminate with high power l.e. d as light source. sor (e&m) 2022 item code 19.10.5 make: havells/ bajaj/crompton/ phillips. 14 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required (d.s.r 2022 e&m code no1.8.3) group c 15 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2x2.5 sq.mm (d.s.r 2022 e&m code no 1.17.11) 16 supply and fixing if 32mm dia. 02 mtr. long g.i pipe (medium class) bracket for mounting of fluorescent/ hpmv/hpsv street light fitting on pole/ wall including bending the pipe to the required shape, 2 nos. 40mmx 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. dsr 2022, item code 12.34 17 workmanship charges for lowering the submersible pump set one no. in re developed bore well, fixing/erection/installation of e&m equipment, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e., eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the tube well will be commissioned on automation mode and timing to be set as per direction of engineer in charge. the all sundry items which are useful & necessary for operation of tube well in automation mode shall be deemed to have been included, whether such items are especially in specification or not. (deep well submersible pump set, insulating mat, sluice valve and nrv will be provided by the department) ...
36942473 repair / renovation of electrical and mechanical equipment of various tube wells under ae ( e and m ) ii. 1. repair/renovation of 03 nos. tube wells under ae(e&m) ii i.e jaccha baccha kendra, mandoli oht, khera village no. 1 tube wells need some renovation work on urgent basis. supply of panel board suitable for 415 volts, 3 phase, 50 hz, 4 wire system for operation of 10 15hp submersible pump set with automatic phase corrector, made out of 2mm thick crca sheet for load bearing members, totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non deteriorating neoprene rubber gaskets. each part of the fabricated panel will be strictly subjected to seven tank treatments. the various components, assemblies and sub equipment of the panel will be as per standard given in relevant is. the bus bar shall be aluminum rectangular cross section size 20 mm x 5 mm strip per phase, rating 100 amp. the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized. the bus bar will be covered with heat shrinkable pvc sleeve throughout in red, yellow & blue color to identify three phases & black for neutral. the bus bar support insulator made of non deteriorating, vermin proof, non hygroscopic materials such as smc/dmc. the control wiring of the panel will be done with pvc flexible copper wires of 1.5mm cross section. each wire will be terminating with a copper ferule crimped to the wire. the panel will have ms angle stand in 50x50x5mm size. size of panel 1360 mm (h) x 760 mm (w) 300mm (d). having mccb 63amp. 415v, 50hz 18 ka tpn of high breaking capacity, 1 no., power contactor 220v 32amp. – 3 nos. (with aux contact block), thermal overload protection relay 9 – 15 amp. – 01 no., star delta timer – 01 no., digital timer switch – 01 no., motor protection relay (under voltage/over voltage/under current/ dry run/ single phase preventer) 8 – 22 amp. – 1 no, capacitor unit (5) kvar – 1 no., indicating lights ryb – 6 nos., on off – 1 set, amp. meter digital 0 – 50a size 96 x 96 mm – 1 no., volt meter (digital type) 0 – 500v size 96 x 96mm – 1 no, controls mcb tpn 32 amp. – 1 no., mcb sp 32 amp. – 1 no., amp. & volt meter selector switches – 1 set, (auto manual reset, 2co contact) – 1 no. change over switch – 1 no., terminal block 6 – way – 1 no., make of accessories: mccb/mcb: l&t/siemens/havells, power contactor: l&t/siemens, timer/relay: l&t/siemens, switchs/push button: l&t/siemens/havells, amp/volt meter: ae/l&t, indicating lights: havells/l&t 2. supply of 80mm dia. b class gi pipe length 3 mtr. with duly welded and threaded flange in both sides, complete with cutting of flange for cable and welded support in both flanges as per site requirement. make: jindal/ parkash/ surya/tata/jindal hisar/jindal ghaziabad. 14 length 3. supply of g.i. tail piece medium class of 0.5 mtrs long including one end flanged and another end threaded of 80mm as per site requirement. 03 no. 4. supply of 80mm dia. gi bend with both side flanges duly welded and threaded as per site requirement. 03 no. 5. supply of m.s. clamp of ms strip duly hole for holding the pipe of 80mm dia. with nut bolts and washer. 03 no. 6. supply of m.s. bore cover made out of ms plate suitable for 10”/12” dia. bore complete with suitable hole for passing the 80mm dia. gi pipe 03 no. 7. supply of nut bolts, washer of good quality as per requirement 75 kg 8. supply of rubber packing sheet with 50 % neoprene (1.5 mm to 25 mm) isi 80 kg mark. (payment will be made as per actual). sor (e&m) item code 22.6.1 9. fabrication/ supply of venturi assembly 80 mm dia. with complete accessories as required at site. 03 job 10. 36w led fixture with led lamp, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver. sor (e&m) item code 19.3.3 make: havells, philips,crompton 08 nos. 11. supply of 45w l.e.d light energy saving & environmental friendly long life versatile pressure die cast aluminum ip 66 roadway laminate with high power l.e. d as light source. sor (e&m) item code 19.10.5 make: havells/ bajaj/crompton/ phillips. 05 nos. 12. wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required (d.s.r 2018 e&m code no1.8.3)group c 15 point 13. supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 2x2.5 sq.mm (d.s.r 2018 e&m code no 1.17.11) 270 mtr. 14. supply and fixing if 32mm dia. 02 mtr. long g.i pipe (medium class) bracket for mounting of fluorescent/ hpmv/hpsv street light fitting on pole/ wall including bending the pipe to the required shape, 2 nos. 40mmx 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. dsr 2018, item code 12.34 05 nos 15. workmanship charges for lowering the submersible pump set one no. in redeveloped bore well, fixing/erection/installation of e&m equipment, accessories, testing and commissioning on load with satisfactory functioning of pump. the work includes all sundry required items for completion of work, i.e., eccentric taper, rubber gasket, necessary reinforcement and vibration isolation arrangement, etc. and loading, unloading, cartage, making good all damages caused during installation and restoring the same to their original finish as required, adequate safety provision, barricading, warning signal and other safety measures while executing the work or wherever necessary so as to avoid accident. the components of the installation shall be of such design so as to satisfactory function under all conditions. the tube well will be commissioned on automation mode and timing to be set as per direction of engineer incharge. the all sundry items which are useful & necessary for operation of tube well in automation mode shall be deemed to have been included, whether such items are especially in specification or not. ...
36892862 tender for providing laying and jointing 160 / 110 mm od hdpe water pipe line from newly bore well at kanganheri village in matiala constituency under ee ( m ) 34...
36649163 tender for erection of repair to gskv c 2 yamuna vihar delhi. dg. 2022 2023. ( sh installation of 02 nos bore well ) ....
36595385 maintenance contract of bore well of line 8 stations ( botanical garden to janakpuri west ) including kalindi kunj depot and other rss and ancillary buildings....
36534449 eor to gskv, gokalpur village, delhi 110094 ( school id 1104021 ) ( sh installation of bore well ) ....
36481828 tender for maintenance of electrical installation fans including pump set compound lighting etc at dte staff qtrs at sawan park delhi sh moei rmo pump sets round the clock operation & maintenance i / c attending and rectifying complaints of all electrical installations i / c compound light & drinking water supply pump etc. installed in the campus in all working days including sundays and holidays by providing following staff etc. as required ( a ) wiremen cum pump cum e&m operator 1 nos in each shift ( b ) khallasi 1 nos in general shift and as and when required 2 supplying & fixing of following electrical accessories suitable for existing different type fitting / switch box i / c testing etc. as required. ( labour already included in item no. 1 ) a ) s.p. 5 / 6 a, one way modular switch, isi marked 3 b ) s.p. 15 / 16 a, one way modular switch, isi marked 4 c ) 3 pin 5 / 6 a modular socket outlet, isi marked 5 d ) 6 pin 15 / 16 a modular socket outlet, isi marked 6 e ) stepped type modular fan regulator ( 2 module ) 7 f ) s.p. 5 / 6 a, one way switch, piano type isi marked 8 g ) s.p. 15 / 16 a, one way switch, piano type isi marked 9 h ) 3 pin 5 / 6 a socket outlet, piano type isi marked 10 i ) 6 pin 15 / 16 & 5 / 6 a socket outlet, piano type isi marked 11 j ) bell push, piano type 12 k ) pvc batten / angle holder 13 l ) 1 or 2 module cover plate 14 m ) 3 module cover plate 15 n ) 8 module cover plate 16 o ) 12 module cover plate 17 p ) step type fan regulator ( socket type piano ) 18 supplying & fixing of 3mm thick phenolic laminated sheet on existing switch board, loose wire box making holes etc as reqd. 19 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. a ) group b 20 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required.a ) group a 21 b ) group b 22 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as requireda ) 3 x 1.5 sq. mm 23 b ) 3 x 4 sq. mm 24 c ) 3 x 6 sq. mm 25 supplying and fixing of following sizes ofsteel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as requireda ) 20 mm 26 b ) 25 mm 27 supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5 / 6 a socket outlet and 5 / 6 a piano type switch, connections, painting etc. as required. 28 supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 / 6 a & 15 / 16 a socket outlet and 15 / 16 a piano type switch, connections, painting etc. as required. 29 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6 a modular socket outlet and 5 / 6 a modular switch, connections etc. as required. 30 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 a & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 31 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, testing etc. as required. 32 supplying and fixing metal box of following sizes ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.a ) 180 mm x 100 mm x 60 mm deep 33 b ) 200 mm x 250 mm x 75 mm deep 34 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) a ) 12 way, double door 35 supplying and fixing cable end box ( loose wire box ) ( ip 43 ) suitable for following single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with testing and commissioning etc. as required.a ) for 12 way, double door spn mcbdb 36 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.a ) single pole 37 b ) single pole and neutral 38 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a ) 100 a, 16 ka, tpmccb 39 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc..direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a ) 63 mm dia ( od 63 mm & id 51 mm nominal ) 40 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal pipe as required.a ) upto 35 sq. mm 41 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. a ) upto 35 sq. mm ( clamped with 1mm thick saddle ) 42 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required 43 supplying, installation, testing and commissioning of pre wired, indoor led batten with extruded aluminium housing & opal diffuser. ip20 of following types suitable for cool day light having cct ( 5700k to 6500k ) , power factor >0.90, cri > 75 ( including dismantling the old fitting if any wherever required ) & minimum lumens output should be > 90 lumens per watt. with all accessories etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. b ) 1x20 wattsled batten fitting. 44 supplying & fixing of decorative, wall mounting, brushed nickel / ss finish fixture with opal glass diffuser suitable for 9 w led lamp b22 base i / c 9 w led lamp complete with connection testing commissioning etc as reqd. 45 supply, installation, testing and commissioning of 1200 mm sweep, bee star rated, ceiling fan, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 215 cmm, 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing with 1.5 sqmm fr pvc insulated copper conductor single core cable etc complete as required. 46 supplying and installation of heavy duty exhaust fan of 300 mm sweep 900 rpm in the existing opening, i / c making the hole suitable the size of the above fan making good the damage, connection testing commisioning with 1.5 sqmm fr pvc insulated copper conductor single core cable etc as reqd. 47 supplying & fixing aluminium louvers / shutters complete with frame suitable for 300 mm sweep exhaust fan etc as reqd. 48 rewinding of 1200 / 1400 mm ceiling fan with suitable size super enamelled copper wire after dismantling from the existing position and refixing the same on the existing position / ceiling with suitable size nut, bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of fan and cleaning the fan and fan blade with detergent and making connection with 1.5 sq. mm frls pvc insulated, copper conductor wire, testing and commissioning etc. complete as required and buy back the dismantled material. 49 dismentling, overhauling & reinstallation of existing ceiling fan complete with cleaning, greasing, replacement of bush, suitable ball bearing, split pin, nuts and bolts, etc with test run i / c credit of dismentle materials etc as reqd. 50 replacement of defective ball bearing in the existing ceiling fans i / c greasing complete etc. as reqd.a ) 6201 51 b ) 6202 52 sitc of pole / wall mounted box ( 300x200x105 ) mm size made out of ( smc ) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i / c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required.a ) 32 amp 5 way connector with backelite base.b ) 6 amp sp mcb c curve ( 10 ka ) 1 no.c ) earth studs 2 sets.d ) 40 x 5 mm clamp with 2 nos. 3 / 8 nut & bolts 1 sete ) push & clip handle to close / open 1 no. 53 repairing of following capacity of submersible / monobloc pumpset i / c replacement of mechanical seal tc / tc upper, mechanical seal tc / tc lower, ball bearing, o ring, stamping repairing, including dismantling, assembling, commissioning and testing the same on load after making electric connections at site i / c site visit by engineer and to and fro from site to workshop & back to site etc.complete with credit of dismantle etc as required.a ) 3 hp 54 b ) 15 hp 55 rewinding of following capacity 3 phase multi stage submersible / mono submersible pump set with suitable size water proof copper conductor wire i / c brazing metalling turning & polishing of shaft, replacement of gm bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i / c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd.a ) 3 hp 56 b ) 15 hp 57 liftingof existing submersible bore well / open well 3 hp to 10 hp capacity pump set from the bore well with chain pulley block & tripod stand i / c cartage charge at site from the work shop. 58 lowering of 3 hp to 10 hp capacity bore well / open well pumpset in the bore well with chain pulley block and tripod stand i / c cartage charge pump set from work shop to site credit of old dismantle etc, as reqd. 59 sitc of 5 hp / 3.75 kw submersible pump starter having relay range 6 10a suitable for 415v 50hz, 3 phase motor complete with sheet enclosure, ammeter, voltmeter, start stop push button, on off led indication lamp and all other accessories including connections & testing credit of dismantle etc complete as required. 60 supplying & fixing / laying of 3 core 2.5 sq.mm flat water proof copper conductor submersible cable i / c connection for submersible pumpset etc. complete as reqd....
36450071 providing or fixing of piezometers device to measure ground water level of bore wells at d 8 okhla vihar, near shiya masjid okhla vihar, near iqbal faizi hospital okhla vihar, near ramesh gupta store jasola village and bore well near a one bekary...
36324723 re boring of tube well at guru arjun nagar, west patel nagar and redevelopment of various bore well of patel nagar constituency under ee ( m ) 24 ac 24 patel nagar....
36324717 re boring of tube well at guru arjun nagar, west patel nagar and redevelopment of various bore well of patel nagar constituency under ee ( m ) 24 ac 24 patel nagar....
36185756 auction sale of misc. mixed scrap, consisting of 3ph motor, sump pump, water cooler, air cooler, cp brass with ss scrap, rs 1 supply fan motors and condenser fan motors, panto carban strip, rs 6 heater coils, ait heater coil, refrigerator, rs 1 back compressor starter winding, mh light fittings, bore well pump, bore well motor, ballasts of different types and capacity, spdb panel, indicator lamp, chocks, ceiling fan without blade, exhaust fan motor with or without blade, electric storage water heater ( geyser ) , hologen light, air compressor motor, geared motor, car fan, brake unit, rs 6 heater, rs 2 heater rod, hand blower etc....
36134778 bids are invited for 1 title1 supply installation testing and commissioning of mono colour flood light luminaire 50 watt in red, green, blue and warm white colour made out of pressure die cast aluminium body and clear pc cover and standard beam angle of 30 deg consistency in multi purpose application like column lighting tree up lighting statue accentuation etc. compelte as required. 2 title2 supply of multicore alumunium conductor xlpe insulated armoured cable 1.1 kv grade confirming to is 7098 part1 complete with all amendments etc. as required. 2 x 6 sq mm 3 title3 supply of multicore alumunium conductor xlpe insulated armoured cable 1.1 kv grade confirming to is 7098 part 1 complete with all amendments etc. as required. 3.5 x 95 sq mm 4 title4 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket bend couplers etc conforming to is 14930 part il complete with fitting and cutting, jointing etc.direct in ground 75 cm below ground level including excavation and refilling the trench but excluding sand cushioning and protective covering etccomplete as required 63 mm dia od 63 mm and id 51mm nominal dsr 2022 p no 43 5 title5 supplying and laying 6 swg g.i. wire at 0.50 metre below ground level for conductor earth electrode including connection termination with gi thimble etc. as required dsr 2022 p no 23 6 title6 providing and fixing6 swg g.i. dai gi wire on surface or in recess for loop earthing along with exiting surface orrecessed cundting submain wiring cale asrequired dsr 2022 p no 24 7 title7 laying of one number pvc insuated and pvc sheathedxlpe power cable of 1.1 kv grade offollowing size in the existing rcc or hume or metal pipe as required. upto 35 sq. mm dsr 2022 p no. 26 8 title8 laying and fixing of one number pvc insuated and pvc sheathedxlpe power cable of 1.1 kv grade offollowing size on cable tray as required. above 35 sq and upto 95 sq mm clampped with 25x3 mm ms flat clamp dsr 2022 p no.27 9 title9 supplying and laying copper conductor round flexible cable size 1.5sq mm core 1100 volt confirming to is 694 connection testing etc as required. 10 title 10 laying of one number pvc insuated and pvc sheathedxlpe power cable of 1.1 kv grade offollowing size direct in ground incl. excavation sand cushining protective covering and reffing the trench etc as requied above 95 sq. and upto 95sq. mmdsr 2022. p no26 11 title 11 supplyingand installation ms frame with connector box suitable to accomodate 50 watt led flood light complete with painting etc. as required. 12 title 12 development of tube well in accordance with is 2800 part i and is 11189 to establish maximum rate of usable water yield without sand content beyond permissible limit with required capacity air compressor running the compressor for required time till well is fully developed. measuring yield of well by v notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory ifc disinfection of tube well all complete including hire and labour charges of air compressor tools andaccessories etc all as per requirement and direction of engineer in charge dsr 2019 13 title13 supplying and installation gi pipe b class size 50 mm complete with suitable g i fittings etc as required. i c rebate of old material 14 title14 lowering and lifting of existing 3.5 hp submersible pump set etc. complete as required. 15 title15 supplying and drawing flat three core pvc insulated and pvc sheathed copper cable size 2.5 sq mm complete with connection testing etc as required i c rebate of old material. 16 title16 providing and fixing bore cap suitable for 150 mm dai bore well to protect the bore well complete with welding work, nut bolt, washer etc. as required ife rebate of old material. 17 title17 repair and rewinding of sub. motors of following capacity with cartage dismantling, reassembling i c supply and replacementrepairing of damaged parts of motors and making good for operation testing painting etc complete as reqd. 5 hp 3 ph sub motor 18 title18 repairing of sub pump of flowing stages and dia with cartage dismantling reassembling supply and replacement repairing of damaged parts of pump and making good for operation i c testing painting etc. complete as required upto all stages 6 inches dia sub. pump set 19 title19 sitc direct on line submersible starter panel three phase etc. as required i cless cost of replaced item item is5 hp relay 6 to 10 20 title20 sitc direct on line submersible starter panel three phase etc. as required i cless cost of replaced item item is 7.5 hp relay 13 to 21 21 title21 supplying and replacement of following accessories in the existing borewell such as ifc rebate of old material reducer 50 mm x 40 mm 22 title22 supplying and replacement of following accessories in the existing borewell such as ifc rebate of old material supporting clamp with nut bolts 50 mm 23 title23 supplying and replacement of following accessories in the existing borewell such as ifc rebate of old material ci flange 50 mm with rubber paking 24 title24 supplying and replacement of following accessories in the existing borewell such as ifc rebate of old material gi socket 50 mm 25 title25 supplying and replacement of casing pipe 150mm confirming to is 3589 gr330 6.35 mm thickness complete with cutting welding threading drilling etc as required i c rebate of old material 26 title26 sitc of submersible pump set 7.5 hp 7 stage rated current 29 ampconnection testing etc as required. 27 title27 sitc of pressure boosting pumping system 1 hp with 24 ltr. tank complete with suitable size fitting dry run protection device etc. as required 28 title28 sitc of panel made out of 16 swg crca sheet duly powder coated suitable to accomodate 250 a fp mccb 36 ka with tm rls for ol equal to sc with rof. 100 a fp mccb 10 ka with tm rls for ol equal to sc with rof 04. tac contact 04, ip digital ammeter 96 mm, cl 1.0 suitable range 01. ip digital voltmeter 96 mm 0 to 500v, meterimng cts 160 divided 5. ind light red yellow blue ete as required 29 title29 repair and rewinding of sub open well pump set motors of following capacity with cartage dismantling. reassembling icsupply and replacement and repairing of damaged parts of motors and making good for operation i c connection testing painting etc. complete as reqd. 5 hp. 3 ph sub ope well pump motor 30 title30 sitc of led fountain light water proof red green blue 18 watt stainless steel body etc as requied 31 title31 supplying and laying copper conductor round flexible cable size 1.5 sq mm 4 core 1100 volt conferming to is 694 connection testing etc as required 32 title32 sitc of programmer and sequincer suitable for 8 led lights etc as required....
36035514 supply of fresh bore well water at ertl(n), new delhi supply of fresh bore well water at ertl(n), new delhi...
36011065 job required for repair to existing bore well 250 mm bore near cvd depot pump house area of age (u) water supply no 1 under ge (u) water supply, delhi cantt 10...
35865242 tender for maintenance of various sports complexes.sub head: running maintenance & operation of internal electrical installations, external lighting, i / c semi high mast lighting, d.g sets, substation equipment and repairing, lowering, lifting of submersible pumps in nssc, jasola, under electrical division 3 running operation & preventive maintenance of electrical installations, home lighting, external lighting internal lighting and d.g. set as per terms and conditions attached by deploying 1 no. operator cum wireman ( skilled ) and 1 no. khallasi in one shifts ( total 3 nos. operator cum wireman and 3 nos khallasi ) etc. as required. 2 supplying and replacement ( including deduction of cost for replaced item ) of pvc insulated copper wire of following size in the existing surface / recessed conduit i / c connection, testing etc. as required.a ) 1x 1.5 sq.mm 3 b ) 1x 2.5 sq.mm 4 c ) 1x 4.0 sq.mm 5 supplying and replacement ( i / c deduction of cost for replaced item ) 6 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. a ) single pole 6 b ) double pole 7 c ) triple pole 8 d ) triple pole and neutral 9 supply and replacement ( i / c deduction of cost for replaced item ) of following led lights with all accessories i / c connection interconnection and testing etc as required. ( with lumens per watt>110 ) a ) 20watt aluminum battan ( 1200 mm long ) led light with ip :20 fixed on surface of wall and roof 10 b ) 15 watt fixture ( 300mmx300mm long ) led light with ip:20 fixed on surface / recess of roof 11 c ) 36 watt fixture ( 600mmx600mm long ) led light with ip :20 fixed on surface / recess of roof 12 d ) 25 watt led pressure die cast aluminium housing, toughened glass cover with ip 66 led street luminaries.led light notmorethan25wandnotlesserthan 2750lux 13 e ) 45 watt led pressure die cast aluminium housing, toughened glass cover with ip 66 ( 14 supplying and replacement ( i / c deduction of cost for replaced item ) following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as requireda ) 5 / 6 a switch 15 b ) 15 / 16 a switch 16 c ) 3 pin 5 / 6a socket outlet 17 d ) 6 pin 15 / 16 a socket outlet 18 supplying and replacement ( including deduction of cost for replaced item ) of following sizes of aluminum conductor xlpe insulatedpvc inner sheathed armoured cable 1.1 kv grade confirming to is:7098 ( part i ) complete with all amendments etc as required: a ) 2 x 16 sq.mm 19 b ) 4x50 sq.mm 20 supply and replacement ( including deduction of cost for replaced item ) of fan fixing the same on existing opening with suitable nut bolt fixture and connection, testing, operating 220 volts etc as reqd. a ) 1200 mm ceiling fan 21 repairing, servicing and calibration of ht, lt panel and dehydration of transformer of following capacities.a ) de hydration and filtrationof transformer oil for 400 kva with filter machine at site to maintain the break down value die electric strength of oil at least 50 kv including providing oil testing facility at site for transformer etc as required qty. 390 ltr. 22 a ) servicing of 11kv h.t. vcb 630 amp complete with cleaning alignment, adjustment of gaps between phases, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required. 23 b ) testing and calibration of h.t idmt relay with secondary injection test set i / c, cleaning servicing of contacts tightening of loose contacts testing repair etc. complete as required. 24 c ) servicing / overhauling crompton make l.t acb 1000 amp with cleaning, alignment, adjustment of gap between phase, lubricating all moving parts adjustment for smooth mechanical operation etc complete as required. 25 d ) calibration of relays, ht / lt meters, temperature meter, buckles relays and servicing of 11 kv vacuum circuit breakers of ht panel kirloskar make along with oiling, greasing of all movable and fire mechanism included checking of contact, resistance and measuring the vacuum level on the desired voltage level with respect each pole. 26 servicing and “b” check of the 380 kva ( cummins make model ) from oem / authorized dealer i / c following items: a ) fuel filter 27 b ) fuel water separator 28 c ) element lub oil filter 29 d ) corrosion inhibitor 30 e ) strip test 31 f ) valvoline premium blue 7800 plus 1 / 20 ltr 32 g ) element ( outer ) 33 h ) element ( inner ) 34 i ) towards the b check maintenance service charges for your cummins dg set 35 servicing and “b” check of the 30 kva ( kirloskar make model ) from oem / authorized dealer i / c following items:a ) engine oil 5 litre 36 b ) fuel filter element ( primary ) 37 c ) fuel filter elment ( secondary ) 38 d ) oil filter 39 e ) air filter 40 f ) koel care coolant 41 g ) radiator descaling 42 lifting of sub pump set of 3hp / 5hp / 7hpcapacity from existing bore well along with existing gi pipe, sub cable, cable holding clamp and transportation as required. 43 assembling and lowering of submersible pump set 3hp / 5hp / 7hp capacity in the existing bore well alongwith g.i. pipe i / c cable jointing, binding of cable with g.i. pipe, connection & testing complete as required. 44 supply and fixing of led flood light, led flood lightnot more than 200 w led and not lesser than 24000 lux with main housing made of pressure die casting with uniform thickness and proper heat sink design to ensure fast heat dissipation. the leds should be mounted on mcpcb and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. the luminaire should be designed for l70 for a minimum 50 k burning hours at an ambient of 45 degrees. the led should be provide with proper secondary lens assembly to insure require beam shaping is specification. the secondary lens assembly should be mounted mcpcb with screws. the leds mounted on the front side of the body should be permanently cover fitted with a clear toughened glass. this ensures the led assembly is free from dust / moisture / water entry ( ip 66 ) . the ik rating should be > ik 08. operating temperature 10 degrees to 50 degrees celsius....
35800043 reboring of bore well at c 5 block keshavpuram and wazirpur village ward no. 75 n in ac 17 wazirpur constituency ( re invited ) ....
35767796 supply of heating appliances and other electric items at bikaner house new delhi 1 supply of bis certified oil filled radiator having 11 fins with temperature control setting sound free operation with minimum 1 year warranty & temperature setting, rated voltage: 230 v, rated wattage: 2400 w made out from crca sheet with powder coating, tubular type element castor wheel, 1.5 mtr pvc power cord along with 16 amp plug top. net weight should not be less then 12 kg and minimum dimensions are 520 x 165 x 710mm complete in all respect. 2 supply of heat blower with two heat settings : 1000 w / 2000 w , adjustable thermostat for desired temprature with minimum 1 year warranty. rated voltage : 230 v , rated wattage: 1000 / 2000 w , 1.5 mtr pvc power cord along with 16 amp plug top. complete in all respect. 3 supply of heater with two heat settings : 1000 w / 2000 w , adjustable thermostat for desired temprature with minimum 1 year warranty. rated voltage : 230 v , rated wattage: 1000 / 2000 w , 1.5 mtr pvc power cord along with 16 amp plug top. complete in all respect. 4 supply of purification capacity 25 lph, duty cycle 170 250 liters / day ro water system with filtration stage = particulate filter membrane life enhancer filter sediment filter pre carbon filter ro membrane filter post carbon filter, input power rating 230 v ac , 50 hz, percentage of rejection tds 90% or better having following features ( a ) double purification by ro with ess or latest technology with tds indicator ( b ) .spin welded ro membrane housing to prevent tempering ( c ) . push fit components for leak proof performance ( d ) . fully automatic operation with auto start and auto off ( e ) . ss / abs construction for corrosion free lifespan ( f ) . equally suitable for water from all bore wells, , overhead storage tanks, water tankers and even municipal taps ( g ) ro membrane flushing auto flush @ every start , every stop and every one hour of working for one minute complete in all respect....
35547850 provision of bore well at mujeeb bagh campus at jamia millia islamia....